BINDER Climate Chamber MK720-400V-C
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Condenser Fan Cleaning
Safety Precautions
Turn off the chamber at the main power switch
Disconnect the power plug
Ensure the chamber does not become wet during operation or maintenance
Authorized Personnel
Confirm maintenance is conducted by licensed electricians or authorized experts
Verify refrigeration system maintenance is conducted by qualified personnel trained according to EN 13313:2010
Condenser Fan Cleaning
Inspect the condenser fan for dust accumulation
1 Monthly Display Status Check
Status Display Check
Check the status display on the rear panel
Action Based on Status Display
Is the status display green?
Is the status display yellow?
Is the status display red?
1 Yearly Climate Chamber Maintenance
Safety Precautions
Pre-Maintenance Safety Checks
Turn off the chamber at the main power switch and disconnect the power plug.
Is the chamber dry and free from moisture?
Personnel Requirements
Is the maintenance being conducted by licensed electricians or experts authorized by BINDER?
Is the refrigeration system work being conducted by qualified personnel trained according to EN 13313:2010?
Refrigeration System Maintenance
Conduct a leak test in accordance with Regulation (EU) 517/2014 (Article 4 and Article 10 (1) (b)).
1 Weekly Condenser Fan Grid Check
Safety Precautions
Turn off the chamber at the main power switch
Disconnect the power plug
Ensure the chamber is not wet during operation or maintenance
Confirm the rear panel of the chamber is not removed
Personnel Requirements
Is the maintenance work being conducted by a licensed electrician or authorized expert?
Is the refrigeration system maintenance conducted by qualified personnel trained according to EN 13313:2010?
Fan Grid Inspection
Climate Chamber Cleaning
Safety Precautions
Turn off the chamber at the main power switch and disconnect the power plug.
Wear protective gloves and goggles.
Ensure no water or cleaning agents are spilled over the inner and outer surfaces.
Cleaning Procedure
Select cleaning agents for exterior surfaces, inner chamber, racks, door gaskets
Select cleaning agents for instrument panel
Select cleaning agents for zinc coated hinge parts, rear chamber wall
Wipe the surfaces with a moistened towel.
Access the parts list for your equipment in MaintainX.
Rack, Stainless Steel
6004-0102
Perforated Rack, Stainless Steel
8009-0511
Reinforced Rack with Rack Lockings, Stainless Steel
8012-0684
Rack Lockings, 4 Pieces
8012-0620
Door Gasket Silicone Inside
6005-0199
Rack, Stainless Steel
6004-0102
Perforated Rack, Stainless Steel
8009-0511
Reinforced Rack with Rack Lockings, Stainless Steel
8012-0684
Rack Lockings, 4 Pieces
8012-0620
Door Gasket Silicone Inside
6005-0199
Rack, Stainless Steel
6004-0102
Perforated Rack, Stainless Steel
8009-0511
Reinforced Rack with Rack Lockings, Stainless Steel
8012-0684
Rack Lockings, 4 Pieces
8012-0620
Door Gasket Silicone Inside
6005-0199
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX