Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

ThermoFisher Scientific Centrifuge 75002420
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Centrifuge Service
Decontamination
Ensure decontamination level is achieved according to requirements
Rinse the centrifuge and all affected accessories with water
Allow to fully drain and dry
Treat the entire surface of aluminum parts including the cavities with corrosion protection oil (70009824)
Safety Precautions
Ensure no one is at risk during decontamination
Verify that decontamination methods or agents will not damage the equipment
Observe safety precautions and handling instructions for decontamination agents used
Aerosol Tightness Testing
Preparation
Lubricate all seals lightly
Use the supplied grease for lubrication
Testing Procedure
Fill the cavities with approx. 10 ml of carbonated mineral water
Close the rotor as per handling instructions
Shake the rotor vigorously using your hands
Check for leaks by observing escaping water or listening for escaping gas
Replace the seals if any leaks are detected and repeat the test
Centrifuge Cleaning
Cleaning Preparation
Ensure all parts are ready for cleaning
Separate rotor, buckets, lids, tubes, and sealing rings
Cleaning Process
Rinse rotor and accessories with warm water and neutral detergent
Use a soft brush without metal bristles to remove stubborn residue
Rinse rotor and accessories with distilled water
Drying Process
Place rotors on a plastic grate with cavities pointing down
Centrifuge Maintenance
Disinfection
Is the level of disinfection achieved according to your requirements?
Rinse the centrifuge and all affected accessories with water.
Allow the centrifuge and accessories to fully drain and dry.
Treat the entire surface of aluminum parts including the cavities with corrosion protection oil (70009824).
Safety Precautions
Ensure no one is put at risk in case of contamination.
Disinfect affected parts immediately if contamination occurs.
Confirm that the disinfection method or agent will not damage the equipment.
Filter Unit Cleaning
Pull the centrifuge to the edge of the table
Remove the filter unit
Pull the clip below the sucking grid
Remove the filter unit completely by pulling it down
Remove the cumulated dust with a soft cloth
Reinsert the filter unit
Ensure the labeling 'Front' is facing the front of the centrifuge
Push the filter upwards into the slot until the clip locks in the bottom plate
Access the parts list for your equipment in MaintainX.
24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid
75003424
Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid
75003418
36 x 0.5 mL Rotor with Screw-on Lid
75003436
10 x 5 mL Rotor with ClickSeal Biocontainment Lid
75003465
PCR 8 x 8 Rotor with Screw-on Lid
75003489
24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid
75003424
Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid
75003418
36 x 0.5 mL Rotor with Screw-on Lid
75003436
10 x 5 mL Rotor with ClickSeal Biocontainment Lid
75003465
PCR 8 x 8 Rotor with Screw-on Lid
75003489
24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid
75003424
Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid
75003418
36 x 0.5 mL Rotor with Screw-on Lid
75003436
10 x 5 mL Rotor with ClickSeal Biocontainment Lid
75003465
PCR 8 x 8 Rotor with Screw-on Lid
75003489
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX