MaintainX Asset Hub logo
EnterprisePricing
ThermoFisher Scientific

ThermoFisher Scientific Centrifuge 75002422

Need answers fast?
Explore the manual using AI.

ThermoFisher Scientific Centrifuge 75002422
ThermoFisher Scientific Centrifuge 75002422

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

ThermoFisher Scientific Centrifuge 75002422

ThermoFisher Scientific Centrifuge 75002422

Create an account to install this asset package.

Maintenance Plans for ThermoFisher Scientific Centrifuge Model 75002422

Integrate maintenance plans directly into your work orders in MaintainX.

Seal Replacement

Check mark

Seal Preparation

Check mark

Lubricate all seals

Check mark

Seal Installation

Check mark

Press the large seal in the outer groove of the rotor body (top detail)

Check mark

Press the small seal into the groove of the rotor collar (bottom detail)

Check mark

Rotor Loading and Inspection

Check mark

Ensure that the rotor lid closes securely

Check mark

Check if the rotor lid is damaged or dulled

Check mark

Replace the rotor lid if it is damaged or dulled

Run this procedureArrow right

Aerosol Tightness Check

Check mark

Initial Inspection

Check mark

Inspect seals and seal surfaces for signs of wear and damage

Check mark

Are all seals and seal surfaces free from damage?

Check mark

Operational Check

Check mark

Is the rotor lid properly closed?

Check mark

Were the sample vessels filled and closed correctly?

Check mark

Final Verification

Check mark

Confirm aerosol tightness of the rotor and buckets

Run this procedureArrow right

Centrifuge Maintenance

Check mark

Disinfection

Check mark

Ensure the level of disinfection is achieved according to requirements

Check mark

Rinse the centrifuge and all affected accessories with water

Check mark

Allow the centrifuge and accessories to fully drain and dry

Check mark

Treat the entire surface of aluminum parts including the cavities with corrosion protection oil (70009824) after disinfecting

Check mark

Safety Precautions

Check mark

Ensure no one is put at risk in case of contamination

Check mark

Verify that disinfection methods or agents will not damage the equipment

Check mark

Contact the manufacturer of the disinfection agent if in doubt

Run this procedureArrow right

13 Yearly Centrifuge Replacement

Check mark

Decommissioning the Centrifuge

Check mark

Has the centrifuge reached its 13-year lifetime limit?

Check mark

Decommission the centrifuge if the lifetime limit is reached.

Check mark

Rotor, Buckets, and Lids Inspection

Check mark

Enter the number of cycles for each rotor.

Check mark

Is the number of cycles within the specified limit for each rotor?

Check mark

Replace rotors, buckets, and lids if they exceed the specified cycle limit.

Check mark

Inspection of Other Accessories

Check mark

Check for damage or wear on accessories

Run this procedureArrow right

Centrifuge Cleaning

Check mark

Cleaning Preparation

Check mark

Ensure all parts are ready for cleaning

Check mark

Separate rotor, buckets, lids, tubes, and sealing rings

Check mark

Cleaning Process

Check mark

Rinse rotor and accessories with warm water and neutral detergent

Check mark

Use a soft brush without metal bristles to remove stubborn residue

Check mark

Rinse rotor and accessories with distilled water

Check mark

Drying Process

Check mark

Place rotors on a plastic grate with cavities pointing down

Run this procedureArrow right

Parts for ThermoFisher Scientific Centrifuge 75002422

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid

75003424

Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid

75003418

36 x 0.5 mL Rotor with Screw-on Lid

75003436

10 x 5 mL Rotor with ClickSeal Biocontainment Lid

75003465

PCR 8 x 8 Rotor with Screw-on Lid

75003489

24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid

75003424

Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid

75003418

36 x 0.5 mL Rotor with Screw-on Lid

75003436

10 x 5 mL Rotor with ClickSeal Biocontainment Lid

75003465

PCR 8 x 8 Rotor with Screw-on Lid

75003489

24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid

75003424

Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid

75003418

36 x 0.5 mL Rotor with Screw-on Lid

75003436

10 x 5 mL Rotor with ClickSeal Biocontainment Lid

75003465

PCR 8 x 8 Rotor with Screw-on Lid

75003489

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from ThermoFisher Scientific

Explore Other Assets