MaintainX Asset Hub logo
EnterprisePricing
ThermoFisher Scientific

ThermoFisher Scientific Centrifuge 75002410

Need answers fast?
Explore the manual using AI.

ThermoFisher Scientific Centrifuge 75002410
ThermoFisher Scientific Centrifuge 75002410

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

ThermoFisher Scientific Centrifuge 75002410

ThermoFisher Scientific Centrifuge 75002410

Create an account to install this asset package.

Maintenance Plans for ThermoFisher Scientific Centrifuge Model 75002410

Integrate maintenance plans directly into your work orders in MaintainX.

Centrifuge Cleaning

Check mark

Cleaning Preparation

Check mark

Ensure all parts are ready for cleaning

Check mark

Separate rotor, buckets, lids, tubes and sealing rings for thorough cleaning

Check mark

Cleaning Process

Check mark

Rinse rotor and all accessories with warm water and neutral detergent

Check mark

Use a soft brush without metal bristles to remove stubborn residue

Check mark

Rinse rotor and all accessories with distilled water

Check mark

Drying Process

Check mark

Place rotors on a plastic grate with cavities pointing down to drain and dry

Run this procedureArrow right

1 Yearly Centrifuge Maintenance

Check mark

Pre-Service Preparation

Check mark

Clean the centrifuge and rotors thoroughly

Check mark

Decontaminate the centrifuge and rotors

Check mark

Service Inspection

Check mark

Check the following components

Check mark

Post-Service Actions

Check mark

Were any repairs necessary?

Check mark

Enter the cost of repairs (if any)

Check mark

Was the centrifuge maintained by an authorized Thermo Fisher Scientific service technician?

Run this procedureArrow right

Aerosol Tightness Check

Check mark

Initial Inspection

Check mark

Inspect seals and seal surfaces for signs of wear and damage

Check mark

Are all seals and seal surfaces free from damage?

Check mark

Operational Check

Check mark

Is the rotor lid properly closed?

Check mark

Are the sample vessels filled and closed correctly?

Check mark

Final Verification

Check mark

Verify aerosol tightness of the rotor and buckets

Run this procedureArrow right

Centrifuge Service

Check mark

Decontamination

Check mark

Ensure decontamination level is achieved according to requirements

Check mark

Rinse the centrifuge and all affected accessories with water

Check mark

Allow to fully drain and dry

Check mark

Treat the entire surface of aluminum parts including the cavities with corrosion protection oil (70009824)

Check mark

Safety Precautions

Check mark

Ensure no one is at risk of contamination

Check mark

Verify that contaminated parts are not touched

Check mark

Describe any contamination incidents and actions taken

Run this procedureArrow right

13 Yearly Centrifuge Replacement

Check mark

Decommissioning the Centrifuge

Check mark

Has the centrifuge reached its 13-year lifetime limit?

Check mark

Decommission the centrifuge if the lifetime limit is reached.

Check mark

Rotor, Buckets, and Lids Inspection

Check mark

Enter the number of cycles for the rotor.

Check mark

Is the rotor within its specified cycle limit?

Check mark

Replace the rotor if it exceeds its cycle limit.

Check mark

Inspect buckets and lids for wear and damage.

Check mark

Replace buckets and lids if damaged or worn.

Run this procedureArrow right

Parts for ThermoFisher Scientific Centrifuge 75002410

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid

75003424

Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid

75003418

36 x 0.5 mL Rotor with Screw-on Lid

75003436

10 x 5 mL Rotor with ClickSeal Biocontainment Lid

75003465

PCR 8 x 8 Rotor with Screw-on Lid

75003489

24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid

75003424

Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid

75003418

36 x 0.5 mL Rotor with Screw-on Lid

75003436

10 x 5 mL Rotor with ClickSeal Biocontainment Lid

75003465

PCR 8 x 8 Rotor with Screw-on Lid

75003489

24 x 1.5/2.0 mL Rotor with ClickSeal Biocontainment Lid

75003424

Dual Row 18 x 2.0/0.5 mL Rotor with Screw-on Lid

75003418

36 x 0.5 mL Rotor with Screw-on Lid

75003436

10 x 5 mL Rotor with ClickSeal Biocontainment Lid

75003465

PCR 8 x 8 Rotor with Screw-on Lid

75003489

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from ThermoFisher Scientific

Explore Other Assets