MaintainX Asset Hub logo
EnterprisePricing
BINDER

BINDER Constant Climate Chamber KBF 130-UL

Need answers fast?
Explore the manual using AI.

BINDER Constant Climate Chamber KBF 130-UL
BINDER Constant Climate Chamber KBF 130-UL

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

BINDER Constant Climate Chamber KBF 130-UL

BINDER Constant Climate Chamber KBF 130-UL

Create an account to install this asset package.

Maintenance Plans for BINDER Constant Climate Chamber Model KBF 130-UL

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Climate Chamber Maintenance

Check mark

Safety Precautions

Check mark

Ensure the chamber is disconnected before maintenance work.

Check mark

Turn off the On/Off switch (H) and pull the power plug.

Check mark

Verify that maintenance work is conducted by licensed electricians or authorized experts.

Check mark

Ensure refrigeration system maintenance is conducted by qualified personnel trained according to EN 13313:2010.

Check mark

General Maintenance

Check mark

Perform regular maintenance work at least once a year.

Check mark

Document all work on the refrigeration system (repairs, inspections).

Check mark

Conduct regular maintenance on the steam humidifier at least once a year.

Run this procedureArrow right

1 Yearly Hose Burst Protection Device Inspection

Check mark

Valve Inspection

Check mark

Demount the safety kit with hose burst protection to check the valve by hand for function, calcification, or blockage.

Check mark

Inspect the valve for calcification.

Check mark

Inspect the valve for blockage.

Check mark

Calcification Removal

Check mark

Remove calcifications using citric acid or acetic acid solutions.

Check mark

Function and Tightness Testing

Check mark

Test the function of the mounted chamber by quickly opening the water tap while there is no chamber connected.

Check mark

Ensure the valve cuts off the water flux without any delay.

Run this procedureArrow right

Climate Chamber Cleaning

Check mark

Safety Precautions

Check mark

Turn off the chamber at the On/Off switch (H) and disconnect the power plug.

Check mark

Ensure the chamber has cooled down to ambient temperature.

Check mark

Wear protective gloves and goggles.

Check mark

Avoid skin contact with the neutral cleaning agent.

Check mark

Cleaning Procedure

Check mark

Thoroughly remove any residues of test material from the chamber.

Check mark

Wipe the surfaces with a moistened towel.

Check mark

Use appropriate cleaning agents for different surfaces

Run this procedureArrow right

1 Yearly Climate Chamber Adjustment

Check mark

Pre-Adjustment Verification

Check mark

Verify the chamber's calibration certificate is up to date

Check mark

Is the test equipment calibrated to DKD-Standard?

Check mark

Adjustment Procedure

Check mark

Perform chamber calibration using standardized test instructions

Check mark

Ensure the following parts are adjusted

Check mark

Post-Adjustment Verification

Check mark

Was the chamber successfully adjusted to meet QM DIN EN ISO 9001 standards?

Check mark

Record any deviations or issues encountered during adjustment

Run this procedureArrow right

1 Yearly Climate Chamber Elecrtrical Test

Check mark

Pre-Test Preparations

Check mark

Ensure the chamber is powered off and disconnected from the main power supply.

Check mark

Verify that all safety equipment is available and in good condition.

Check mark

Inspection and Testing

Check mark

Inspect the following components for any visible damage or wear

Check mark

Perform insulation resistance test according to EN 50678/VDE 0701 standards.

Check mark

Conduct protective conductor resistance test as per EN 50699/VDE 0702 standards.

Check mark

Post-Test Procedures

Check mark

Were all tests completed successfully?

Run this procedureArrow right

Parts for BINDER Constant Climate Chamber KBF 130-UL

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Neutral Cleaning Agent

1002-0016

Disinfectant Spray

1002-0022

Plug, For Silicon Access Port D30

6016-0035

Plug, For Elongated Access Port

6016-0065

External Freshwater And Wastewater Cans, 20 Liters / 0.71 Cu.Ft. Each

8012-2592

Neutral Cleaning Agent

1002-0016

Disinfectant Spray

1002-0022

Plug, For Silicon Access Port D30

6016-0035

Plug, For Elongated Access Port

6016-0065

External Freshwater And Wastewater Cans, 20 Liters / 0.71 Cu.Ft. Each

8012-2592

Neutral Cleaning Agent

1002-0016

Disinfectant Spray

1002-0022

Plug, For Silicon Access Port D30

6016-0035

Plug, For Elongated Access Port

6016-0065

External Freshwater And Wastewater Cans, 20 Liters / 0.71 Cu.Ft. Each

8012-2592

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from BINDER

Explore Other Assets