MaintainX, an Autodesk company
EnterprisePricing
Gardner Denver

Gardner Denver Screw Air Compressor EAU99M 300 HP

Need answers fast?
Explore the manual using AI.

Gardner Denver Screw Air Compressor EAU99M 300 HP
Gardner Denver Screw Air Compressor EAU99M 300 HP

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Gardner Denver Screw Air Compressor EAU99M 300 HP

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Gardner Denver Screw Air Compressor EAU99M 300 HP

Gardner Denver Screw Air Compressor EAU99M 300 HP

Create an account to install this asset package.

Maintenance Plans for Gardner Denver Screw Air Compressor Model EAU99M 300 HP

Integrate maintenance plans directly into your work orders in MaintainX.

Oil Separator Maintenance

Check mark

Preparation

Check mark

Ensure the unit is completely off and no air pressure is in the oil reservoir.

Check mark

Disconnect, tag and lockout power supply to the starter.

Check mark

Separator Removal

Check mark

Remove screws holding the top plate to the separator housing and lift the top plate from the separator housing.

Check mark

Lift the separator from the separator housing.

Check mark

Separator Inspection and Replacement

Check mark

Inspect and/or replace the separator as necessary. Ensure the following are checked:

Check mark

Apply grease to the o-ring before installing or reinstalling the separator.

Run this procedureArrow right

Motor Lubrication

Check mark

Preparation

Check mark

Stop the unit

Check mark

Disconnect, lockout and tagout the unit from the power supply

Check mark

Lubrication Process

Check mark

Remove the relief plug and free hole of hardened grease

Check mark

Wipe lubrication fitting clean

Check mark

Add grease with a hand-operated grease gun

Check mark

Post-Lubrication

Check mark

Leave the relief plug temporarily off

Run this procedureArrow right

8 Hourly Compressor Maintenance

Check mark

Check the reservoir oil level

Check mark

Check the reservoir oil level

Check mark

Add oil if required

Check mark

Refer to “Excessive Oil consumption” if oil consumption is high

Check mark

Observe if the unit loads and unloads properly

Check mark

Check discharge pressure and temperature

Check mark

Enter the discharge pressure

Check mark

Enter the discharge temperature

Check mark

Check Panel LED’s for advisories

Run this procedureArrow right

Air Filter Maintenance

Check mark

Initial Inspection

Check mark

Check if 'CHANGE AIR FILTER' message is displayed

Check mark

Air Filter Servicing

Check mark

Inspect the heavy-duty air filter for dirt and debris

Check mark

Clean the air filter if necessary

Check mark

Replace the air filter if cleaning is insufficient

Check mark

Post Maintenance Check

Check mark

Verify air filter is properly installed

Check mark

Ensure no loss of compressor air delivery

Run this procedureArrow right

Compressor Oil System Check

Check mark

Temperature Checks

Check mark

Record Air and Oil Discharge Temperature

Check mark

Record Compressor Oil Inlet Temperature

Check mark

Pressure Checks

Check mark

Record Oil Inlet Pressure

Check mark

Record Oil Cooler Oil Pressure Differential (Air-Cooled Radiator)

Check mark

Record Oil Cooler Oil Pressure Differential (Water-Cooled Heat Exchanger)

Check mark

Record Oil Cooler Water Pressure Differential (Water-Cooled Heat Exchanger)

Check mark

Temperature Differential Checks

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Gardner Denver

Explore Other Assets