MaintainX, an Autodesk company
EnterprisePricing
Gardner Denver

Gardner Denver Base Mounted Compressor LRS132

Need answers fast?
Explore the manual using AI.

Gardner Denver Base Mounted Compressor LRS132
Gardner Denver Base Mounted Compressor LRS132

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Gardner Denver Base Mounted Compressor LRS132

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Gardner Denver Base Mounted Compressor LRS132

Gardner Denver Base Mounted Compressor LRS132

Create an account to install this asset package.

Maintenance Plans for Gardner Denver Base Mounted Compressor Model LRS132

Integrate maintenance plans directly into your work orders in MaintainX.

125 Hourly Compressor Inspection

Check mark

Safety Precautions

Check mark

Ensure the compressor is not powered before starting maintenance.

Check mark

For L90RS-L132RS models, disconnect the system from the mains and wait 10 minutes before touching electrical components.

Check mark

Press the STOP button on the control panel and wait until the compressor stops and is depressurized.

Check mark

Ensure the pressure gauge shows no more than 4.4 PSI.

Check mark

Relieve the compressor unit by slowly opening the screw plug with integrated air vent slots.

Check mark

Set the on-site main switch to '0' (OFF) and secure it against being switched on.

Check mark

Inspection and Cleaning

Check mark

Check for dirt accumulation on the following components

Run this procedureArrow right

Interceptor Cleaning

Check mark

Danger!

Check mark

Preparation

Check mark

Lock water inflow and water outflow on the compressor.

Check mark

Provide a suitable container to catch any cooling agents draining from the system.

Check mark

Cleaning Process

Check mark

Carefully loosen the cover of the dirt interceptor.

Check mark

Catch any cooling agent draining from the system.

Check mark

Remove cover and pull filter insert from the housing.

Check mark

Clean filter insert or replace with a new one.

Run this procedureArrow right

8 Hourly Compressor Inspection

Check mark

Safety Precautions

Check mark

Ensure the compressor is not powered before starting inspection.

Check mark

For L90RS-L132RS models, confirm the system is disconnected from the mains and wait 10 minutes before touching electrical components.

Check mark

Operational Checks

Check mark

Check the following operational aspects

Check mark

Post-Operation Safety Measures

Check mark

Press the STOP button on the control panel and wait until the compressor stops and is depressurized.

Check mark

Verify the pressure gauge shows no more than 4.4 PSI.

Check mark

Relieve the compressor unit by slowly opening the screw plug with integrated air vent slots.

Run this procedureArrow right

4000 Hourly / 1 Yearly Relief Valve Check

Check mark

Safety Precautions

Check mark

Use appropriate safety equipment, including hearing and eye protection.

Check mark

Ensure all safety precautions are followed when performing the PRV check.

Check mark

Testing the Pressure Relief Valve

Check mark

Test the valve using one of the following methods

Check mark

Note any local legislation considerations during testing.

Check mark

Post-Test Actions

Check mark

Did the pressure relief valve close itself and is not leaky?

Check mark

If the valve is defective

Run this procedureArrow right

8000 Hourly / 2 Yearly Oil Replacement

Check mark

Safety Precautions

Check mark

Shut down the compressor and relieve the system of all pressure.

Check mark

Disconnect, lockout, and tagout the power supply to the compressor package.

Check mark

Hazard Warnings

Check mark

Ensure no oil is spilled to avoid fire and slip hazards.

Check mark

Remove oil residue and other deposits from the compressor coolers.

Check mark

Inspect for leaks and address any spilled oil immediately.

Check mark

Oil Change Procedure

Check mark

Turn off the screw compressor unit and secure it against accidental restarts.

Run this procedureArrow right

Parts for Gardner Denver Base Mounted Compressor LRS132

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Lubrication Oil

AEON 9000SP

Lubrication Oil

AEON 9000SP

Lubrication Oil

AEON 9000SP

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Gardner Denver

Explore Other Assets