MaintainX, an Autodesk company
EnterprisePricing
Gardner Denver

Gardner Denver Base Mounted Compressor L132

Need answers fast?
Explore the manual using AI.

Gardner Denver Base Mounted Compressor L132
Gardner Denver Base Mounted Compressor L132

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Gardner Denver Base Mounted Compressor L132

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Gardner Denver Base Mounted Compressor L132

Gardner Denver Base Mounted Compressor L132

Create an account to install this asset package.

Maintenance Plans for Gardner Denver Base Mounted Compressor Model L132

Integrate maintenance plans directly into your work orders in MaintainX.

8 Hourly Oil Level Check

Check mark

Safety Precautions

Check mark

Shut down the compressor and relieve the system of all pressure.

Check mark

Disconnect, lockout, and tagout the power supply to the compressor package.

Check mark

Oil Level Inspection

Check mark

Shut off the compressor with the STOP button.

Check mark

Wait for 5 minutes to allow the oil to settle.

Check mark

Check the oil level using the transparent plastic tube on the pressure reservoir.

Check mark

Is the oil level between the 'maximum oil level' and 'minimum oil level' marks?

Check mark

Oil Top-Up

Run this procedureArrow right

2000 Hourly / 6 Monthly Compressor Maintenance

Check mark

Safety Precautions

Check mark

Ensure the compressor is not powered before starting maintenance.

Check mark

For L90RS-L132RS models, disconnect the system from the mains and wait 10 minutes before touching electrical components.

Check mark

Ensure the system is depressurized before maintenance.

Check mark

Set the on-site main switch to '0' (OFF) and secure it against being switched on.

Check mark

Be cautious of hot surfaces during maintenance.

Check mark

Filter Maintenance

Check mark

Replace the following filter elements as indicated by the compressor controller

Check mark

Remove the mounting screws of the filter mat.

Run this procedureArrow right

Air Compressor Cleaning

Check mark

Safety Warning

Check mark

Warning! Danger when cleaning system parts with compressed air

Check mark

Caution! Fire hazard from oil residues

Check mark

Blow off the screw compressor with compressed air

Check mark

Blow off controller components

Check mark

Blow off fittings

Check mark

Blow off air end block

Check mark

Blow off cooler

Check mark

Blow off electric motor

Run this procedureArrow right

125 Hourly Compressor Inspection

Check mark

Safety Precautions

Check mark

Ensure the compressor is not powered before starting maintenance.

Check mark

For L90RS-L132RS models, disconnect the system from the mains and wait 10 minutes before touching electrical components.

Check mark

Press the STOP button on the control panel and wait until the compressor stops and is depressurized.

Check mark

Verify the pressure gauge shows no more than 4.4 PSI.

Check mark

Relieve the compressor unit by slowly opening the screw plug with integrated air vent slots.

Check mark

Set the on-site main switch to '0' (OFF) and secure it against being switched on.

Check mark

Inspection and Cleaning

Check mark

Check for dirt accumulation on oil/aftercooler core faces and the cooling fan.

Run this procedureArrow right

4000 Hourly / 1 Yearly Compressor Maintenance

Check mark

Safety Precautions

Check mark

Ensure the compressor is not powered before starting maintenance.

Check mark

For L90RS-L132RS models, disconnect the system from the mains and wait 10 minutes before touching electrical components.

Check mark

Press the STOP button on the control panel and wait until the compressor stops and is depressurized.

Check mark

Check that the pressure gauge shows no more than 4.4 PSI.

Check mark

Open the screw plug (oil filling opening) with integrated air vent slots to relieve any residual pressure.

Check mark

Set the on-site main switch to '0' (OFF) and secure it against being switched on.

Check mark

Be cautious of hot surfaces when performing maintenance.

Check mark

Maintenance Tasks

Run this procedureArrow right

Parts for Gardner Denver Base Mounted Compressor L132

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Lubrication Oil

AEON 9000SP

Lubrication Oil

AEON 9000SP

Lubrication Oil

AEON 9000SP

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Gardner Denver

Explore Other Assets