Manual for Gardner Denver Screw Air Compressor EAU99M 250 HP

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Gardner Denver Screw Air Compressor EAU99M 250 HP

Gardner Denver Screw Air Compressor EAU99M 250 HP

Create an account to install this asset package.

Maintenance Plans for Gardner Denver Screw Air Compressor Model EAU99M 250 HP

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Compressor Maintenance

Check mark

Relief Valve Check

Check mark

Raise system operating pressure to 75% of the relief valve set pressure

Check mark

Manually open the relief valve with the hand lever and hold for a few seconds

Check mark

Check shutdowns for proper operation

Run this procedureArrow right

50 Hourly Filter Element Service

Check mark

Preparation

Check mark

Is the 'CHANGE AIR FILTER' LED illuminated?

Check mark

Ensure genuine Gardner Denver air filter elements are available.

Check mark

Filter Element Removal

Check mark

Unfasten the clips and pull out the filter element.

Check mark

Filter Element Inspection

Check mark

Visually inspect the filter element. Is cleaning necessary?

Check mark

Filter Element Cleaning

Check mark

Soak the element in warm water with mild non-sudsing detergent for 15 minutes.

Run this procedureArrow right

Motor Lubrication

Check mark

Preparation

Check mark

Stop the unit

Check mark

Disconnect, lockout and tagout the unit from the power supply

Check mark

Lubrication Process

Check mark

Remove the relief plug and free hole of hardened grease

Check mark

Wipe lubrication fitting clean

Check mark

Add grease with a hand-operated grease gun

Check mark

Post-Lubrication

Check mark

Leave the relief plug temporarily off

Run this procedureArrow right

Oil Separator Maintenance

Check mark

Preparation

Check mark

Ensure the unit is completely off and no air pressure is in the oil reservoir.

Check mark

Disconnect, tag and lockout power supply to the starter.

Check mark

Separator Removal

Check mark

Remove screws holding the top plate to the separator housing and lift the top plate from the separator housing.

Check mark

Lift the separator from the separator housing.

Check mark

Inspection and Replacement

Check mark

Inspect and/or replace the separator as necessary. Ensure the following are checked:

Check mark

Apply grease to the o-ring before installing or reinstalling the separator.

Run this procedureArrow right

Filter Element Life Maintenance

Check mark

Visual Inspection

Check mark

Inspect the filter element for ruptures, cracks, or pinholes using a bright light inside the element.

Check mark

Pressure Drop Measurement

Check mark

Measure the pressure drop through the filter with a freshly cleaned element while the compressor is running at full load.

Check mark

Is the pressure drop below three (3) inches (76 mm) of water?

Check mark

Replacement Criteria

Check mark

Has the filter element been cleaned six (6) times?

Check mark

Replace the filter element if any of the above conditions are met.

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Gardner Denver

Explore Other Assets