

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Continental Tumble Dryer NJ120L
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Burner Orifice Size Replacement
Preparation
Disconnect electrical power from tumble dryer
Close gas shut-off valve to tumble dryer
Safety Verification
Verify that the supply inlet pressure is equipped with a pressure regulator
Manometer Attachment
Attach manometer to the correct location based on gas valve type
Gas Valve Removal
Remove gas valve components
Gas Valve Governor/Regulator Adjustment
Preparation
Ensure the following tools are available
Refer to Figure 13
Pressure Check
Remove screw plug from pressure tap
Connect a U-tube manometer to the burner orifice pressure tap
Start tumble dryer
Note pressure once flame is burning
Regulator Adjustment
Gas Burner Air Shutter Adjustment
Safety Precautions
Disconnect electric power to the tumble dryer before servicing.
Close gas shut-off valve to gas tumble dryer before servicing.
Close steam valve to steam tumble dryer before servicing.
Ensure all guards/panels are in place before starting the tumble dryer.
Reconnect all ground wires removed during servicing to ensure proper grounding.
Preparation
Remove all lint from lint compartments and lint screen.
Air Shutter Adjustment
1 Yearly Hose Maintenance
Visual Inspection
Check hoses for visible signs of deterioration
Are there any hoses that need replacement?
Replacement
Replace any hose showing signs of deterioration
Final Check
Ensure all replaced hoses are properly installed
Technician's signature
1 Monthly Fire Suppression System Check
Pre-Test Preparations
Inform the fire department about the upcoming test if the auxiliary output is connected to notify them.
Disconnect the auxiliary output if it is connected to activate a building sprinkler.
System Activation Check
Verify the auxiliary output contact activates during the fire suppression system test.
Check the relay rating and ensure it does not exceed 5 Amp, 250VAC.
Post-Test Actions
Reconnect the auxiliary output if it was disconnected prior to the test.
Inform the fire department that the test is complete if they were notified before the test.
Access the parts list for your equipment in MaintainX.
Cold Weather Fire Suppression System Relocation Kit
44340301
Inlet Hose 8.0 Feet
20617
Inlet Hose 10 Feet
20618
Blank Orifice
M400995
Burner Opening Cover
M413099
Cold Weather Fire Suppression System Relocation Kit
44340301
Inlet Hose 8.0 Feet
20617
Inlet Hose 10 Feet
20618
Blank Orifice
M400995
Burner Opening Cover
M413099
Cold Weather Fire Suppression System Relocation Kit
44340301
Inlet Hose 8.0 Feet
20617
Inlet Hose 10 Feet
20618
Blank Orifice
M400995
Burner Opening Cover
M413099
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













