AI feels weightless. We type a prompt, receive an answer, and see no sign of the machinery involved.

But every AI service depends on a massive array of physical assets that power everything from electrical distribution and backup generators to cooling and water systems, networks, fire protection, controls, and the buildings that contain them. Servers may perform the computation, but those supporting systems make sustained operation possible.

That is why data centers can be viewed much like a factory. They both convert energy, equipment, and expertise into a product. For data centers, that product is available computing capacity. And, as in manufacturing, the output depends on many connected systems working together. A failure in one critical support system can limit or interrupt the whole operation.

The reliability of data centers is becoming a bigger priority as their scale grows alongside their impact on everything from the economy to the environment. The International Energy Agency estimates that data centers consumed about 415 terawatt-hours of electricity in 2024, or roughly 1.5% of global electricity use. The share of a facility’s electricity consumption taken up by cooling can vary significantly: the IEA reports a range from about 7% in efficient hyperscale data centers to more than 30% in less-efficient enterprise facilities.

As operators add computing capacity, they also add demand and complexity across the systems that supply power and remove heat. That raises an important question: Are we investing as deliberately in the reliability of those systems as we are in computing capacity?

Reliability-centered maintenance (RCM) offers a practical way to answer that question. It helps teams choose maintenance strategies based on what an asset must do, how it can fail, and what happens when it does. It does not prescribe more maintenance everywhere. It helps determine which tasks are worth doing, where they are effective, and where a different response makes more sense.

An RCM strategy starts with the service the data center must provide

RCM begins by defining the system’s functions and performance standards in its operating context. For a data center, that means looking beyond simply keeping equipment running. The required functions might include supplying stable power within defined limits, maintaining environmental conditions for the GPUs, transferring load to backup equipment, and detecting and responding to fire or water events.

Those functions should reflect the service the facility is expected to deliver. You can determine those services by answering the following:

  • What availability is required? 
  • What operating conditions must be maintained? 
  • What happens during maintenance, a utility disturbance, extreme weather, or an equipment failure? 
  • What are the system limits? 
  • How much redundancy is available?

These questions connect maintenance choices to asset management. ISO 55000 describes asset management as a way to realize value from assets in support of organizational objectives, while balancing considerations such as cost, risk, and performance over the asset lifecycle.

For a data center, “value” may include service availability, safety, energy efficiency, resilience, and the ability to meet customer commitments. The value of a cooling pump or switchgear lineup is not captured by its purchase price alone. Its importance depends on the role it plays in delivering the facility’s required service.

Define functional failures, not just broken components

Once the functions are clear, RCM asks how they can be lost or degraded. A functional failure describes what the system can no longer do to the required standard. A failure mode describes the specific way that loss occurs.

For example, the function may be to maintain cooling-water flow to a critical load. A functional failure could be insufficient flow or loss of flow. Potential failure modes might include pump seizure, a failed drive, a blocked strainer, a leaking valve, or a control-system fault.

A maintenance program built only around equipment labels can miss how failures propagate through interconnected systems. A component might still be running while the system’s required function is already impaired. Conversely, a component fault may have little operational consequence if another independent path continues to provide the service.

NASA’s RCM guide for facilities uses this same logic: analyze system functions, possible failures, failure modes, and their effects and consequences. It also emphasizes that the consequences depend on how and where the asset is used, even when the equipment is similar.

Allow consequences to guide maintenance policy

Instead of simply asking how often an asset should be serviced, also ask what happens if the failure occurs?

A loss of cooling in a high-density computing area may threaten service continuity. A failure in a non-critical area may have a different consequence. A hidden failure in a standby generator or automatic transfer function may remain unnoticed until the system is needed. The maintenance response should reflect those differences.

An RCM analysis may lead to different strategies for different failure modes:

  • Condition-based tasks can detect developing degradation when there is a measurable warning, such as an abnormal vibration trend, temperature, pressure, or electrical signature.
  • Scheduled restoration or replacement can make sense when age or usage is meaningfully related to failure and the task reduces risk.
  • Failure-finding tasks can reveal hidden failures in standby or protective functions, such as transfer schemes, alarms, or backup equipment.
  • Design or operating changes may be needed when maintenance cannot adequately control the risk. For example, where access is poor, a single point of failure remains, or operating practices impose excessive stress.
  • Run-to-failure can be a rational choice for some low-consequence failure modes when the response is understood and planned.

Any maintenance task you create should have a clear purpose, whether it’s to prevent a failure, detect degradation in time to act, reveal a hidden failure, or reduce the consequences. RCM is intended to select a suitable blend of maintenance approaches. SAE’s current JA1011 recommended practice is explicitly framed for organizations managing physical assets and systems responsibly.

Make redundancy something the operation can rely on

Data centers often include redundant equipment and paths. But installed redundancy is not the same as proven resilience. A backup system can be unavailable because of an undetected fault, an incorrect configuration, a maintenance error, a defect in the switching system, or a shared dependency that defeats the apparent redundancy.

RCM helps expose those risks by asking what the function is, how it can fail, and whether the failure would be evident during normal operation. It also directs attention to hidden failures in protective and standby systems. That should lead to maintenance and testing plans that confirm the backup path can perform its required function, not just that an inspection was completed.

This work depends on coordination among facilities engineering, operations, maintenance, IT, safety, and vendors. A maintenance window that appears acceptable from one team’s perspective could change the risk profile of the entire facility. Clear asset hierarchies, accurate equipment records, good failure coding, and controlled procedures help teams understand those dependencies and learn from events.

Use data to improve decisions, not just add monitoring

Data centers can generate substantial equipment and condition data. Sensors and analytics can help identify abnormal patterns, but only if the data is reliable and connected to a decision process.

For each monitoring point, teams should be able to explain what failure mode it detects, what threshold or trend will trigger action, who reviews the result, and what work follows. Otherwise, more data can produce more alarms and dashboards without improving reliability.

The same discipline applies to maintenance metrics. Work order completion, PM compliance, availability, mean time to repair, energy use, and repeat failures can all be useful, but none tell the full story. A useful review asks whether important failure modes are being controlled, whether planned work is reducing exposure to risk, whether tests reveal hidden failures, and whether actions taken after incidents have measurably improved performance.

Treat reliability as part of the asset lifecycle

Maintenance is only one part of the answer. Reliability decisions begin during design and procurement, when teams choose system architecture, redundancy, maintainability, access, monitoring, and supplier support. They continue through commissioning, operations, upgrades, and eventual replacement.

An RCM analysis can inform those lifecycle decisions. If a failure mode cannot be detected early enough, or if the consequence is too severe for the available maintenance strategy, the answer may involve redesign, improved isolation, different operating limits, better spare parts planning, or a change in system configuration. This is where reliability engineering can give decision-makers evidence about performance and risk, while lifecycle planning determines how to act on that evidence.

The broader context includes sustainability. Power and cooling systems affect the facility’s energy and resource use. Reliability can support efficiency by reducing avoidable losses, emergency interventions, and premature replacement, but those benefits should be measured against the data center’s actual operating conditions and service requirements. The goal is to find a responsible balance between service, risk, cost, and resource use.

The infrastructure behind scientific progress

As Data centers become more reliable, more efficient, computing power becomes more accessible just as electricity, cars, and airplanes become reliable, available and accessible. The fact that those advancements became accessible transformed the world and the same is happening with Computing Power and what comes with it, scientific advancement.  

The implications reach beyond commercial computing. The 2024 Nobel Prize in Chemistry recognized David Baker for computational protein design and Demis Hassabis and John Jumper for protein structure prediction, which is a breakthrough for development of new treatments and drugs.

A reliable data center does not create a scientific discovery by itself. Researchers, methods, data, and institutions do that work. But stable and accessible computing infrastructure can help make intensive analysis and collaboration possible. For that reason, reliability in the physical systems behind computing is part of a larger chain of capability.

Data centers are factories for digital services. Their reliability depends on much more than servers. RCM gives operators a structured way to protect the functions that matter, choose maintenance based on failure consequences, and identify when a maintenance task is not enough.

The central challenge is to make asset decisions that support dependable service across the full lifecycle, while accounting for cost, risk, energy, and the people responsible for operating the systems.

As data center capacity expands, how will we make sure the power, cooling, and protection systems behind it are managed with the same discipline as the computing equipment they support?

Reliability-centered maintenance for data centers FAQs

Why are data centers compared to factories?

They rely on interconnected physical systems—power, cooling, backup generation, and controls—to deliver a continuous service.

What is Reliability-Centered Maintenance (RCM)?

RCM is a structured way to choose maintenance based on an asset’s required functions, potential failure modes, and the consequences of failure.

How can RCM improve data center reliability?

It helps teams focus maintenance on the systems and failure modes that pose the greatest risk to service, safety, or the environment.

Which data center assets should be prioritized for maintenance?

Priorities should reflect each asset’s role, redundancy, failure consequences, and the facility’s required service level—not just equipment cost or age.

How should data centers maintain backup power systems?

Maintenance should verify that generators, UPS systems, batteries, transfer switches, and related controls can perform their required functions when called upon.

Why is cooling system reliability critical in a data center?

Cooling helps maintain operating conditions for IT equipment. A cooling failure can threaten equipment performance and service continuity.

Does RCM mean more preventive maintenance?

No. RCM helps determine whether preventive, condition-based, failure-finding, corrective, or run-to-failure approaches are appropriate for each failure mode.

How does asset management support data center reliability?

Asset management connects operational performance and maintenance decisions with lifecycle cost, risk, service objectives, and sustainability.

Can predictive maintenance prevent data center outages?

It can help detect some developing failures, but it works best when condition data is reliable and teams have clear thresholds, owners, and response plans.

How can data centers measure maintenance effectiveness?

Teams can review service availability, repeat failures, backup-system test results, maintenance-related incidents, energy use, and whether actions reduced identified risks.

What is a hidden failure in a data center?

It is a failure that is not obvious during normal operation, such as a fault in a standby or protective system that is only discovered when tested or needed.

author photo

Geraldo Signorini is a Principal Industry Manager at Autodesk where he helps manufacturers build operational excellence into the way their teams work every day. A continuous improvement leader with over 16 years of enterprise and multi-site experience, he has established, deployed, and sustained operational excellence systems across global manufacturing environments.

‍

Learn more

View related procedures to improve your maintenance operations

No items found.
“MaintainX is innovative and nimble. They provide an intuitive solution to help take your reliability program to the next level.”
See MaintainX in action
Fields marked with an asterisk (*) are required.

Fields marked with an asterisk (*) are required.

By submitting the form, you acknowledge our Privacy Policy.

By submitting the form, you acknowledge our Privacy Policy.
Thank you
Oops! Something went wrong while submitting the form.