

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mitsubishi Outdoor Unit MUZ-SF50VE
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Defrost Setting Changing
Warning: This procedure requires trained personnel!
JS wire of the outdoor Inverter P.C. board cut/soldered?
Select the model of the unit
Enter the defrost finish temperature
Sign off on the defrost setting change
Pre-Heat Control Setting
Warning: This procedure requires trained personnel with PPE!
Enter the discharge temperature thermistor reading
Is the discharge temperature thermistor reading 20°C or below?
If the discharge temperature thermistor reading is 20°C or below, the pre-heat control should turn ON.
Did the pre-heat control turn ON?
If the pre-heat control turned ON, the compressor should be energized.
Is the compressor energized?
To activate the pre-heat control, cut JK wire of the inverter P.C. board.
Upload a photo of the cut JK wire
Access the parts list for your equipment in MaintainX.
Top Panel
E12 F28 297
Outdoor Heat Exchanger
E12 H21 630
Outdoor Fan Motor, Symbol - MF, Model - RC0J60
E12 G16 301
Propeller Fan
E12 F28 501
Handle
E12 817 009
Top Panel
E12 F28 297
Outdoor Heat Exchanger
E12 H21 630
Outdoor Fan Motor, Symbol - MF, Model - RC0J60
E12 G16 301
Propeller Fan
E12 F28 501
Handle
E12 817 009
Top Panel
E12 F28 297
Outdoor Heat Exchanger
E12 H21 630
Outdoor Fan Motor, Symbol - MF, Model - RC0J60
E12 G16 301
Propeller Fan
E12 F28 501
Handle
E12 817 009
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













