MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Outdoor Unit MXZ-4C36NAHZ2-U1

Need answers fast?
Explore the manual using AI.

Mitsubishi Outdoor Unit MXZ-4C36NAHZ2-U1
Mitsubishi Outdoor Unit MXZ-4C36NAHZ2-U1

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Outdoor Unit MXZ-4C36NAHZ2-U1

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Outdoor Unit MXZ-4C36NAHZ2-U1

Mitsubishi Outdoor Unit MXZ-4C36NAHZ2-U1

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Outdoor Unit Model MXZ-4C36NAHZ2-U1

Integrate maintenance plans directly into your work orders in MaintainX.

4-Way Valve Coil Replacement

Check mark

Warning: Ensure the power is off before starting the procedure

Check mark

Service panel removed

Check mark

Upload a photo of the removed service panel

Check mark

4-way valve coil fixing screw removed

Check mark

4-way valve coil removed

Check mark

Upload a photo of the removed 4-way valve coil

Check mark

Connector 21S4 disconnected

Check mark

Sign off on the 4-way valve coil replacement

Run this procedureArrow right

Reactor Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the electrical parts box

Check mark

Upload a photo of the removed electrical parts box

Check mark

Remove 6 screws (4 x 10) for reactor

Check mark

Upload a photo of the removed screws

Check mark

Remove the reactors

Run this procedureArrow right

Compressor Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the cover panel (front)

Check mark

Remove the cover panel (rear)

Check mark

Remove the side panel (R)

Check mark

Remove 2 front cover panel fixing screws (5 × 12) and remove the cover panel (front)

Check mark

Upload a photo of the removed front cover panel

Run this procedureArrow right

Bypass Valve Coil Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the cover panel (front)

Check mark

Remove the cover panel (rear)

Check mark

Remove the side panel (R)

Check mark

Remove the bypass valve coil fixing screw (M4 × 6)

Check mark

Remove the bypass valve coil by sliding the coil upward

Run this procedureArrow right

Thermistor Ambient Replacement

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Disconnect the connector TH7/6 (red) on the multi controller circuit board in the electrical parts box

Check mark

Loosen the wire clamps on top of the electrical parts box

Check mark

Upload a photo of the loosened wire clamps

Check mark

Pull out the thermistor <Ambient> (TH7) from the sensor holder

Check mark

Note: When replacing thermistor <Ambient> (TH7), replace it together with thermistor <Suction pipe> (TH6), since they are combined together.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets