Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner MXZ-8C48NA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Outdoor Unit Refrigirant Charging
Cautions for service
Refrigerant recovered from the unit completely
Refrigerant not released in the air
Cycle charged with specified amount of refrigerant after service
Filter drier installed for service
Filter drier for new refrigerant used
Additional refrigerant charge
Cylinder for R410A is a syphon type
Charging performed with the cylinder of syphon stood vertically
Fan Motor Replacement
Warning: Ensure the power is off before starting the procedure
Upload Photo 1 after removing the service panel
Upload Photo 1 after removing the top panel
Upload Photo 1 after detaching the fan grille
Upload Photo 2 after detaching the propeller
Disconnect the connectors, CNF1 and CNF2 on multi controller circuit board in electrical parts box
Upload Photo 3 after detaching the fan motor
Enter the torque used to tighten the propeller fan
Sign off on the fan motor replacement
TH2/TH3 And TH4 Thermistors Replacement
Service panel removed
Upload a photo of the removed service panel
Connectors TH3 (white), TH4 (white), and TH2 (black) disconnected
Clamp for the lead wire loosened
Thermistor <Outdoor liquid pipe> (TH3) and thermistor <Compressor> (TH4) pulled out from the sensor holder
Upload a photo of the thermistors after removal
Sign off on the thermistors replacement
Low Pressure Sensore Replacement
Remove the service panel
Upload a photo of the removed service panel
Remove the top panel
Upload a photo of the removed top panel
Remove the cover panel (front)
Remove the cover panel (rear)
Remove the side panel (R)
Disconnect the connector 63LS (blue) on the multi controller circuit board in the electrical parts box
Upload a photo of the disconnected connector 63LS
Electronic Expansion Valve Replacement
Upload a photo of the service panel after removal
Upload a photo of the top panel after removal
Refer to procedure 8 (5) for removing the cover panel (front)
Refer to procedure 8 (6) for removing the cover panel (rear)
Refer to procedure 8 (7) for removing the side panel (R)
Upload a photo of the electrical expansion valve coil after removal
Upload a photo of the electrical parts box after removal
Refrigerant recovered successfully?
Upload a photo of the welded part of electrical expansion valve after removal
Access the parts list for your equipment in MaintainX.
Inverter Starter Type, Hermetic Compressor - 3,4 KW
ANB33FNHMT
Inverter Starter Type, Hermetic Compressor - 3,4 KW
ANB33FNHMT
Inverter Starter Type, Hermetic Compressor - 3,4 KW
ANB33FNHMT
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX