MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Outdoor Unit MUY-D30NA

Need answers fast?
Explore the manual using AI.

Mitsubishi Outdoor Unit MUY-D30NA
Mitsubishi Outdoor Unit MUY-D30NA

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Outdoor Unit MUY-D30NA

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Outdoor Unit MUY-D30NA

Mitsubishi Outdoor Unit MUY-D30NA

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Outdoor Unit Model MUY-D30NA

Integrate maintenance plans directly into your work orders in MaintainX.

Thermistors Replacement

Check mark

Remove the top panel, cabinet, service panel and the back panel

Check mark

Disconnect the Electronic control P.C. board

Check mark

Disconnect CN661 (Discharge temperature thermistor, defrost thermistor (MUZ) and outdoor heat exchanger temperature thermistor)

Check mark

Disconnect CN663 (Ambient temperature thermistor)

Check mark

Pull out the defrost thermistor from its holder (MUZ)

Check mark

Pull out the discharge temperature thermistor from its holder

Check mark

Pull out the outdoor heat exchanger temperature thermistor from its holder

Check mark

Pull out the ambient temperature thermistor from its holder

Check mark

Sign off on the thermistors replacement

Run this procedureArrow right

Compressor And 4-Way Valve Replacement

Check mark

Remove the top panel, cabinet, service panel and the back panel

Check mark

Remove the inverter assembly

Check mark

Remove the R.V. coil

Check mark

Recover gas from the refrigerant circuit until the pressure gauge shows 0 PSIG

Check mark

Detach the brazed part of the suction and the discharge pipe connected with compressor

Check mark

Remove the compressor nuts

Check mark

Remove the compressor

Check mark

Detach the brazed part of 4-way valve and pipe

Check mark

Sign off on the compressor and 4-way valve replacement

Run this procedureArrow right

Cabinet Replacement

Check mark

Remove the screws of the service panel

Check mark

Remove the screws of the top panel

Check mark

Remove the screw of the valve cover

Check mark

Remove the service panel

Check mark

Remove the top panel

Check mark

Remove the valve cover

Check mark

Remove the screws of the cabinet

Check mark

Remove the cabinet

Check mark

Remove the screws of the back panel

Run this procedureArrow right

Reactor Replacement

Check mark

Warning: This procedure should be performed by trained personnel only

Check mark

Top panel removed

Check mark

Cabinet removed

Check mark

Service panel removed

Check mark

Back panel removed

Check mark

Reactor lead wire disconnected

Check mark

Reactor screws removed

Check mark

Reactor removed

Check mark

Sign off on the reactor replacement

Run this procedureArrow right

Fan Motor Replacement

Check mark

Remove the top panel, cabinet, service panel and the back panel

Check mark

Disconnect the following connectors: <Electronic control P.C. board> CN931 and CN932 (Fan motor)

Check mark

Remove the propeller

Check mark

Remove the screws fixing the outdoor fan motor

Check mark

Remove the outdoor fan motor

Run this procedureArrow right

Parts for Mitsubishi Outdoor Unit MUY-D30NA

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Compressor

TNB220FMCHT

Compressor

TNB220FMCHT

Compressor

TNB220FMCHT

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets