Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Howden Roots Air Blower URAI 22
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3000 Hourly Gear End Oil Change
Lubrication — How to properly determine the oil service intervals
Check ambient temperature and discharge temperature
Determine oil viscosity grade based on temperature
Verify oil temperature does not exceed 195°F (90°C)
Oil Change Procedure
Remove the breather plug (25) and the oil overflow plug (21)
Fill the reservoir up to the overflow hole
Ensure the reservoir is not overfilled
Place the breather and the overflow plug back into their respective holes
3 Weekly Drive End Bearing Lubrication
Lubrication — For Units with grease lubricated drive end
Select the operating speed range
Enter the operating hours per day
Use the specified NLGI #2 premium grade aluminium complex grease, Roots P/N T20019002
Ensure no lithium based grease is used
Technical supplement for URAI-G Gas blowers — Lubrication
Check hydraulic pressure relief fittings for venting excess grease
Ensure restriction plug and metering orifice are in place
Use a pressure gun to slowly force new lubricant into each drive end bearing housing
750 Hourly Gear End Oil Change
Lubrication — How to properly determine the oil service intervals
Check ambient temperature and discharge temperature
Determine oil viscosity grade based on conditions
Use Roots synthetic oil of correct viscosity per Table 2
Remove the breather plug (25) and the oil overflow plug (21)
Fill the gearbox reservoir up to the overflow hole
Ensure the reservoir is not overfilled
Place the breather and the overflow plug back into their respective holes
1500 Hourly Gear End Oil Change
Lubrication — How to properly determine the oil service intervals
Determine the oil service intervals based on conditions
Oil Specification and Filling
Select the correct oil viscosity grade based on conditions
Use Roots synthetic oil of correct viscosity per Table 2
Remove the breather plug (25) and the oil overflow plug (21)
Fill the reservoir up to the overflow hole
Ensure the reservoir is not overfilled
Place the breather and the overflow plug back into their respective holes
5 Weekly Drive End Bearing Lubrication
Lubrication — For Units with grease lubricated drive end
Verify the following conditions
Use specified NLGI #2 premium grade aluminium complex grease, Roots P/N T20019002
Ensure no lithium based grease is used
Technical supplement for URAI-G Gas blowers — Lubrication
Check hydraulic pressure relief fittings for proper venting
Ensure restriction plug and metering orifice are in place
Use a manual pressure gun to lubricate drive end bearing housing
Use specified NLGI #2 premium grade aluminum complex grease, Roots P/N T20019002
Access the parts list for your equipment in MaintainX.
Roots Synthetic Oil ISO-VG-220 — Quart
813-106-001
Roots Synthetic Oil ISO-VG-220 — Gallon
813-106-002
Roots Synthetic Oil ISO-VG-220 — Case 12 qt
813-106-008
Roots Synthetic Oil ISO-VG-320 — Quart
813-106-004
Roots Synthetic Oil ISO-VG-320 — Gallon
813-106-005
Roots Synthetic Oil ISO-VG-220 — Quart
813-106-001
Roots Synthetic Oil ISO-VG-220 — Gallon
813-106-002
Roots Synthetic Oil ISO-VG-220 — Case 12 qt
813-106-008
Roots Synthetic Oil ISO-VG-320 — Quart
813-106-004
Roots Synthetic Oil ISO-VG-320 — Gallon
813-106-005
Roots Synthetic Oil ISO-VG-220 — Quart
813-106-001
Roots Synthetic Oil ISO-VG-220 — Gallon
813-106-002
Roots Synthetic Oil ISO-VG-220 — Case 12 qt
813-106-008
Roots Synthetic Oil ISO-VG-320 — Quart
813-106-004
Roots Synthetic Oil ISO-VG-320 — Gallon
813-106-005
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX