MaintainX Asset Hub logo
EnterprisePricing
TECO

TECO Electric Motor AEHH8NJP/JM

Need answers fast?
Explore the manual using AI.

TECO Electric Motor AEHH8NJP/JM
TECO Electric Motor AEHH8NJP/JM

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for TECO Electric Motor AEHH8NJP/JM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

TECO Electric Motor AEHH8NJP/JM

TECO Electric Motor AEHH8NJP/JM

Create an account to install this asset package.

Maintenance Plans for TECO Electric Motor Model AEHH8NJP/JM

Integrate maintenance plans directly into your work orders in MaintainX.

Anti-Friction Bearings Oil Change

Check mark

5.5.5 Oil Re-lubrication

Check mark

Change the oil at regular intervals

Check mark

Determine the interval for oil changes based on operating conditions

Check mark

Is the ambient temperature high, requiring more frequent oil changes?

Check mark

Avoid operating the motor with oxidized oil

Check mark

Use only good grade, oxidation-corrosion-inhibited turbine oils from reputable companies

Check mark

Is the ambient temperature near or below freezing?

Check mark

Preheat the oil or use special oil if necessary

Check mark

Use the lubrication oil stipulated on the lubrication nameplate, if attached

Run this procedureArrow right

Sleeve Bearing Re-Assembly

Check mark

5.6.4 Re-assembly

Check mark

Clean the interior of the bearing housing and flush with clean oil or kerosene

Check mark

Wipe the bearing halves and shaft journal with a lint-free cloth soaked in clean oil

Check mark

Inspect all parts for imperfections

Check mark

Remove imperfections using appropriate methods such as stoning, scraping, or filing, followed by thorough cleaning

Check mark

Is the floating labyrinth seal free of cracks or chips?

Check mark

Ensure the bottom half seal's drilled holes are positioned at the bottom toward the inside of the bearing

Check mark

Apply a bead of Curil-T around the seal half O.D.'s on both sides adjacent to the garter spring groove

Check mark

Place the bottom seal half on top of the shaft and roll it into position

Run this procedureArrow right

Anti-Friction Bearings Oil Level Check

Check mark

Oil Level Inspection

Check mark

Check the oil level in the sight gauge

Check mark

Is the oil level within the recommended operating range?

Check mark

If the oil level is above the maximum, drain enough oil to bring it back within the recommended range

Check mark

If the oil level is below the minimum, add oil to reach the recommended range

Check mark

Post-Inspection Actions

Check mark

Investigate for oil leaks if excessive amounts of make-up oil were added

Check mark

Record any issues found during the inspection

Check mark

Final Check

Run this procedureArrow right

2 Weekly Tilt-Pad Bearing Storage Maintenance

Check mark

Bearing protection — tilt-pad bearings

Check mark

Rotate the shaft a few revolutions

Check mark

Pour in approximately one cup of oil

Run this procedureArrow right

Valve Inspection

Check mark

5.8.2 Valve Inspection

Check mark

Inspect the check valve for any signs of wear or damage

Check mark

Inspect the stop valve for any signs of wear or damage

Check mark

Ensure the check valve is protecting the pump from reverse flow and excessive backpressure

Check mark

Ensure the stop valve is functioning correctly during priming, starting, and shutdown of the pump

Check mark

Close the stop valve before stopping the pump, especially when operated against a high static head

Check mark

Record any issues found during the inspection

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from TECO

Explore Other Assets