MaintainX Asset Hub logo
EnterprisePricing
Baldor Reliance

Baldor Reliance Electric Motor JMM3613T

Need answers fast?
Explore the manual using AI.

Baldor Reliance Electric Motor JMM3613T
Baldor Reliance Electric Motor JMM3613T

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Baldor Reliance Electric Motor JMM3613T

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Baldor Reliance Electric Motor JMM3613T

Baldor Reliance Electric Motor JMM3613T

Create an account to install this asset package.

Maintenance Plans for Baldor Reliance Electric Motor Model JMM3613T

Integrate maintenance plans directly into your work orders in MaintainX.

3 Monthly Motor Maintenance

Check mark

Storage — Non-Regreaseable Motors

Check mark

Rotate the motor shaft 15 times to redistribute the grease within the bearing

Check mark

Storage — step 5b

Check mark

Rotate ball and roller bearing motor shafts manually

Check mark

Has the motor been greased in the last 6 months?

Run this procedureArrow right

1 Monthly Motor Insulation Resistance Testing

Check mark

Storage — Preparation for Storage

Check mark

Measure and record the resistance of the winding insulation (dielectric withstand) every 30 days of storage

Check mark

Place new desiccant inside the vapor bag and re-seal by taping it closed

Check mark

Place the shell over the motor and secure with lag bolts

Check mark

Storage — Minimum insulation resistance

Check mark

Enter the minimum resistance of motor winding insulation

Check mark

Calculate and record the minimum resistance using the formula Rm = kV + 1

Run this procedureArrow right

1 Monthly Sleeve Bearing Maintenance

Check mark

Storage

Check mark

Ensure sleeve bearing (oil lube) motors are drained of oil prior to shipment

Check mark

Refill oil reservoirs to the indicated level with the specified lubricant

Check mark

Rotate the shaft by hand for 10 to 15 revolutions to distribute oil to bearing surfaces

Run this procedureArrow right

2 Monthly Anti-Friction Bearing Re-Lubrication

Check mark

Section 3 — Lubrication Procedure

Check mark

Ensure lubrication is done with the motor stationary and warm

Check mark

Locate the grease inlet, clean the area, and replace the pipe plug with a grease fitting if necessary

Check mark

Remove relief plug and clean around it

Check mark

Is there severe caking at the plug?

Check mark

Run the motor until the bearing housing is warm if severe caking is present

Check mark

Locate the motor nameplate and find the recommended lubricant type and volume

Check mark

Add the recommended volume of lubricant using a hand-operated grease gun

Check mark

Run the motor for 2 hours with the relief plug removed

Run this procedureArrow right

1 Monthly Anti-Friction Bearing Re-Lubrication

Check mark

Section 3 — Lubrication Procedure

Check mark

Relubrication with the shaft stationary and a warm motor is recommended

Check mark

Locate the grease inlet, clean the area and replace the pipe plug with a grease fitting, if the motor is not equipped with grease fittings

Check mark

Remove relief plug

Check mark

Clean caked grease around the plug with a wooden stick or suitable tool

Check mark

If severe caking appears at the plug, run the motor until the bearing housing is warm

Check mark

Locate the motor nameplate to find the recommended lubricant type and volume

Check mark

Add the recommended volume of the recommended lubricant using a hand operated grease gun

Check mark

Run the motor for 2 hours with relief plug removed

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Baldor Reliance

Explore Other Assets