MaintainX Logo
EnterprisePricing
Okuma

Okuma Lathe LU 15 MY

Need answers fast?
Explore the manual using AI.

Okuma Lathe LU 15 MY
Okuma Lathe LU 15 MY

The Okuma Lathe LU 15 MY is a high-precision CNC lathe designed for versatile machining applications. Known for its reliability and advanced features, this model enhances productivity in various industrial settings, making it an essential asset for manufacturers seeking efficiency and quality.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Okuma Lathe LU 15 MY

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Okuma Lathe LU 15 MY

Okuma Lathe LU 15 MY

Create an account to install this asset package.

Maintenance Plans for Okuma Lathe Model LU 15 MY

Integrate maintenance plans directly into your work orders in MaintainX.

8000 Hourly / 3 Yearly Consumable Items Replacement

Check mark

Oil seals replaced

Check mark

Wipres replaced

Check mark

Timing belt replaced

Check mark

Packings replaced

Check mark

Z ring replaced

Check mark

X rings replaced

Check mark

Piston seal replaced

Check mark

Cap seal replaced

Check mark

Dust seal replaced

Run this procedureArrow right

Coolant Tank Cleaning

Check mark

Remove the cover at the side of the coolant tank

Check mark

Draw the coolant out of the tank by the pump

Check mark

Pull out the coolant tank to the right until the pump protrudes from the side cover, and pull it out to the front

Check mark

Clean inside the coolant tank

Check mark

Clean the filter

Check mark

After cleaning the tank, refill the coolant tank

Check mark

Coolant tank must not protrude from the front rail. If the coolant tank is not installed correctly, coolant will leak

Check mark

Sign off on the coolant tank cleaning

Run this procedureArrow right

Initial 1 Monthly Lathe Maintenance

Check mark

Check the bedways for level and straightness

Check mark

Flush out the hydraulic power unit and change the hydraulic fluid

Check mark

Change cooling oil in the spindle cooling unit

Check mark

Sign off on the lathe maintenance

Run this procedureArrow right

1 Yearly Lower Saddle Wiper Inspection

Check mark

Verify that there is no chip penetration

Check mark

Check the rib wear condition

Check mark

Check for the presence of minute and embedded chips

Check mark

Check for wear at the wiper contact area

Check mark

Verify that felt is free of chips

Check mark

Check to see if the felt has hardened

Run this procedureArrow right

6 Monthly Lathe Maintenacne

Check mark

Change hydraulic oil in the hydraulic unit

Check mark

Supply lubricating oil to the chip conveyor

Check mark

Change cooling oil in the spindle cooling unit

Check mark

Enter the hours on the Oil-air lubrication unit

Check mark

If the hours on the Oil-air lubrication unit exceed 1000, replenish the unit

Check mark

Sign off on the lathe maintenance

Run this procedureArrow right

Parts for Okuma Lathe LU 15 MY

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Hydraulic Unit Line Filter

H0032-0009-17

Hydraulic Unit Solenoid Valve Upper/Lower Turret

F0001-431-000-83

Lower Saddle Dester Block 0.08 x 2 x 1

H0019-0002-91

Oil Leveling Gauge Spindle Cooling Unit

H0039-0004-77

Coolant Pump 250W

F0130-03-000-58

Hydraulic Unit Line Filter

H0032-0009-17

Hydraulic Unit Solenoid Valve Upper/Lower Turret

F0001-431-000-83

Lower Saddle Dester Block 0.08 x 2 x 1

H0019-0002-91

Oil Leveling Gauge Spindle Cooling Unit

H0039-0004-77

Coolant Pump 250W

F0130-03-000-58

Hydraulic Unit Line Filter

H0032-0009-17

Hydraulic Unit Solenoid Valve Upper/Lower Turret

F0001-431-000-83

Lower Saddle Dester Block 0.08 x 2 x 1

H0019-0002-91

Oil Leveling Gauge Spindle Cooling Unit

H0039-0004-77

Coolant Pump 250W

F0130-03-000-58

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Okuma

Explore Other Assets