Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

KSB SE & Co. KGaA Standardised Chemical Pump MCPK050-32-125
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Suction Filter Inspection
Filter Monitoring
Record the differential pressure across the filter
Is the differential pressure within acceptable limits?
Filter Cleaning
Is filter cleaning required based on the pressure reading?
Was the filter cleaned successfully?
Post Inspection
Ensure all tools and equipment are removed from the work area
Dispose of any waste materials properly
Initial Motor Mounting
Check applicability of steps 1 and 2
Shift the motor to connect it to the pump via the coupling
Fasten the motor to the baseplate
Align pump and motor
Connect the motor to the power supply
Impeller Removal
Verify notes and steps from Section 7.4.1 to Section 7.4.4 have been observed/carried out
Ensure the back pull-out unit is in a clean and level assembly area
Undo impeller nut 922 (right-hand thread)
Remove impeller 230 using an impeller removal device
Place impeller 230 on a clean and level surface
Remove keys 940.01 from shaft 210
Remove and dispose of joint rings 411.31/411.32
Clearance Inspection
Back Pull-Out Unit Removal
Remove the back pull-out unit
Clearance Measurement
Measure clearance G, D, E
Is the clearance G, D, E within permissible limits?
Measure clearance C, V
Is the clearance C, V within permissible limits?
Casing Wear Ring Replacement
Fit new casing wear ring if necessary
Bearings Dismantling
Observe and carry out notes and steps from Section 7.4.1 to Section 7.4.6
Ensure the bearing bracket is kept in a clean and level assembly area
Unscrew the hexagon socket head cap screw in the coupling hub
Pull the coupling half off the pump shaft with a puller
Remove key 940.02
Undo screws 914.02 and remove drive-end bearing cover 360.02 and joint ring 400.02
Undo screws 914.01 and remove pump-end bearing cover 360.01 and joint ring 400.01
Access the parts list for your equipment in MaintainX.
Shaft
210
Impeller
230
Rolling Element Bearing (Set)
320.02
Radial Ball Bearing
321.01
Radial Ball Bearing (1)
321.02
Shaft
210
Impeller
230
Rolling Element Bearing (Set)
320.02
Radial Ball Bearing
321.01
Radial Ball Bearing (1)
321.02
Shaft
210
Impeller
230
Rolling Element Bearing (Set)
320.02
Radial Ball Bearing
321.01
Radial Ball Bearing (1)
321.02
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX