MaintainX, an Autodesk company
EnterprisePricing
Genie

Genie Articulated Boom Lift Z 30/20N

Need answers fast?
Explore the manual using AI.

Genie Articulated Boom Lift Z 30/20N
Genie Articulated Boom Lift Z 30/20N

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Genie Articulated Boom Lift Z 30/20N

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Genie Articulated Boom Lift Z 30/20N

Genie Articulated Boom Lift Z 30/20N

Create an account to install this asset package.

Maintenance Plans for Genie Articulated Boom Lift Model Z 30/20N

Integrate maintenance plans directly into your work orders in MaintainX.

3 Monthly Turntable Level Sensor Test

Check mark

Preparation

Check mark

Ensure the machine is on a firm surface with a side slope greater than 2° but less than 5°

Check mark

Ensure the digital level is calibrated to gravity

Check mark

Turn the key switch to ground control and pull out the red Emergency Stop button to the on position at both ground and platform controls

Check mark

Test Turntable Level Sensor - Z-135/70, ZX-135/70, SX-105 XC, SX-125 XC, SX-135 XC, SX-150 and SX-180

Check mark

Place the digital level on the X axis of the turntable

Check mark

Is the reading at the display and digital level within ± 1° of each other?

Check mark

If not, calibrate the level sensor as per the Service and Repair Manual

Check mark

Place the machine on a firm surface with an uphill or downhill slope greater than 2° but less than 5°

Run this procedureArrow right

2000 Hourly / 3 Monthly Hydraulic Oil Maintenance

Check mark

Visual Inspection of Hydraulic Oil

Check mark

Visually inspect the hydraulic oil for the following

Check mark

Oil Testing and Replacement

Check mark

Did the hydraulic oil pass all visual inspections?

Check mark

If the oil failed any inspection, was it tested by an oil distributor?

Check mark

Was the hydraulic oil replaced?

Check mark

Post Replacement Actions

Check mark

Replace all hydraulic filters when replacing the hydraulic oil

Check mark

Continue with scheduled quarterly maintenance inspection after oil replacement

Run this procedureArrow right

3 Monthly Safety Envelope Limit Switch Test

Check mark

- Test the Safety Envelope Limit Switches, Z-135/70, ZX-135/70, SX-105 XC, SX-125 XC, SX-135 XC, SX-150 and SX-180 Models

Check mark

Testing the machine envelope safety limit switches is critical to safe machine operation. If the boom is allowed to operate when a safety switch is not functioning correctly, the machine stability could be compromised and may tip over

Check mark

Note: Perform this procedure with the boom in the stowed position

Check mark

Note: Perform this procedure with the axles extended

Check mark

Note: Two people will be required to perform this procedure

Check mark

Note: Use the following chart to identify the description of each LCD screen control button used in this procedure

Check mark

Z-135/70 and ZX-135/70 Models:

Check mark

Secondary Boom #1 Retracted Safety Limit Switch, LSS1RS

Check mark

1. Working at the platform end of the turntable, support and secure the lower turntable riser end cover to a suitable lifting device

Run this procedureArrow right

3 Monthly Recovery System Test

Check mark

Test the Recovery System - ALC-1000 Models

Check mark

Verify applicable models

Check mark

Preparation

Check mark

Ensure the machine is on a firm, level surface with axles extended

Check mark

Ensure all weight, tools, equipment, and personnel are removed from the platform

Check mark

Initial Setup

Check mark

Turn the key switch to the ground control and pull out the red Emergency Stop button to the on position

Check mark

Start the engine

Check mark

Boom Extension

Run this procedureArrow right

3 Monthly Boom Lift Maintenance

Check mark

Check for Open Bulletins and Owner Registration

Check mark

Document your Genie machine serial number

Check mark

Confirm current machine owner information on file

Check mark

Check for current bulletins for your machine(s)

Run this procedureArrow right

Parts for Genie Articulated Boom Lift Z 30/20N

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Digital Level Kit

58351

Digital Protractor

58377

O-ring Field Service Kit

49612

Digital Level Kit

58351

Digital Protractor

58377

O-ring Field Service Kit

49612

Digital Level Kit

58351

Digital Protractor

58377

O-ring Field Service Kit

49612

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Genie

Explore Other Assets