MaintainX, an Autodesk company
EnterprisePricing
Flowserve

Flowserve Pump Mark 3 2K 4x3-10H

Need answers fast?
Explore the manual using AI.

Flowserve Pump Mark 3 2K 4x3-10H
Flowserve Pump Mark 3 2K 4x3-10H

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Flowserve Pump Mark 3 2K 4x3-10H

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Flowserve Pump Mark 3 2K 4x3-10H

Flowserve Pump Mark 3 2K 4x3-10H

Create an account to install this asset package.

Maintenance Plans for Flowserve Pump Model Mark 3 2K 4x3-10H

Integrate maintenance plans directly into your work orders in MaintainX.

General Maintenance Inspection

Check mark

Maintenance Schedule

Check mark

Monitor auxiliary systems

Check mark

Adjust gland packing for visible leakage and concentric alignment

Check mark

Check for leaks from gaskets and seals

Check mark

Is the shaft seal functioning correctly?

Check mark

Enter bearing lubricant level

Check mark

Enter remaining hours before lubricant change is required

Check mark

Is the duty condition within the safe operating range for the pump?

Check mark

Confirm satisfactory operation

Run this procedureArrow right

Initial 160 Hours Pump Oil Change

Check mark

Pump Lubricants — Oil Bath

Check mark

Record the external bearing housing temperature

Check mark

Is the external bearing housing temperature within the maximum limit?

Check mark

Change the oil after 160 hours of operation

Check mark

Examine and describe any contaminants found in the used oil

Run this procedureArrow right

3 Monthly Pump Grease Lubrication

Check mark

Pump Lubricants — Grease

Check mark

Verify lubrication intervals based on temperature

Check mark

Ensure bearing temperature is 71-80°C (160-175°F)

Check mark

Remove pipe plug from inboard and outboard bearing locations

Check mark

Regrease bearings

Check mark

Have the bearings been relubricated three times?

Check mark

Clean out the bearing housing if relubricated three times

Check mark

Safety Precautions

Check mark

Stop pump and lock the motor

Run this procedureArrow right

3 Monthly Pump Oil Change

Check mark

Pump Lubricants — Oil Bath (Mineral Oil)

Check mark

Verify lubrication intervals based on temperature

Check mark

Is the bearing temperature between 71-80°C (160-175°F)?

Check mark

Fill the bearing housing to the center of the oil sight glass with the proper type oil

Check mark

Ensure no detergent oils are used

Run this procedureArrow right

Sealed Bearing Maintenance

Check mark

Pump Lubricants — Grease for Life

Check mark

Verify that double shielded or double sealed bearings are packed with grease by the manufacturer

Check mark

Confirm that bearings are not relubricated

Check mark

Assess the operating temperature and speed of the bearings

Check mark

Determine if the replacement interval is affected by operating conditions

Check mark

Check if shielded bearings are operating cooler than expected

Run this procedureArrow right

Parts for Flowserve Pump Mark 3 2K 4x3-10H

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Casing

1100

Cover

1220

Adapter - Bearing Housing

1340

Shaft

2100

Impeller

2200

Casing

1100

Cover

1220

Adapter - Bearing Housing

1340

Shaft

2100

Impeller

2200

Casing

1100

Cover

1220

Adapter - Bearing Housing

1340

Shaft

2100

Impeller

2200

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Flowserve

Explore Other Assets