MaintainX, an Autodesk company
EnterprisePricing
Flowserve

Flowserve Pump Mark 3 2K 3x2-10A

Need answers fast?
Explore the manual using AI.

Flowserve Pump Mark 3 2K 3x2-10A
Flowserve Pump Mark 3 2K 3x2-10A

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Flowserve Pump Mark 3 2K 3x2-10A

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Flowserve Pump Mark 3 2K 3x2-10A

Flowserve Pump Mark 3 2K 3x2-10A

Create an account to install this asset package.

Maintenance Plans for Flowserve Pump Model Mark 3 2K 3x2-10A

Integrate maintenance plans directly into your work orders in MaintainX.

Initial Pump Start-Up Check

Check mark

Pre-Commissioning Procedure — Pre Start-Up Checks

Check mark

Ensure all components are properly secured and installed

Check mark

Perform rotation check

Check mark

Verify impeller clearance setting

Check mark

Ensure shaft seal is properly installed

Check mark

Check seal support system operational

Check mark

Verify bearing lubrication

Check mark

Check bearing housing cooling system operational

Check mark

Ensure support leg cooling for centerline mounting option operational

Run this procedureArrow right

6 Monthly Pump Oil Change

Check mark

Pump Lubricants — Oil Bath (Mineral Oil)

Check mark

Verify lubrication interval based on temperature

Check mark

Select oil type

Check mark

Check that the oil is free of contaminants

Check mark

Ensure oil contains rust and oxidation inhibitors

Check mark

Fill the bearing housing to the center of the oil sight glass with the proper type oil

Check mark

Select the pump group and enter the amount of oil required

Check mark

Confirm that detergent oils are not used

Run this procedureArrow right

Sealed Bearing Maintenance

Check mark

Pump Lubricants — Grease for Life

Check mark

Verify the type of bearing

Check mark

Is the bearing packed with grease by the manufacturer?

Check mark

Should the bearing be relubricated?

Check mark

Enter the operating temperature of the bearing

Check mark

Enter the operating speed of the bearing

Check mark

Does the bearing operate cooler than expected?

Run this procedureArrow right

18 Monthly Pump Oil Change

Check mark

Pump Lubricants — Oil Bath (Synthetic Oil)

Check mark

Verify lubrication intervals based on temperature and oil type

Check mark

Ensure use of Royal Purple or Conoco SYNCON (or equivalent) synthetic lubricant

Check mark

Are Viton O-rings required for the synthetic lubricant?

Check mark

Fill the bearing housing to the center of the oil sight glass with the proper type oil

Run this procedureArrow right

6 Weekly Pump Grease Lubrication

Check mark

Pump Lubricants — Grease

Check mark

Verify lubrication intervals based on temperature

Check mark

Remove pipe plug from inboard and outboard bearing locations

Check mark

Regrease the bearings

Check mark

Have the bearings been relubricated three times?

Check mark

Clean out the bearing housing if bearings have been relubricated three times

Check mark

Safety Precautions

Check mark

Stop the pump

Check mark

Lock the motor

Run this procedureArrow right

Parts for Flowserve Pump Mark 3 2K 3x2-10A

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Casing

1100

Cover

1220

Adapter - Bearing Housing

1340

Shaft

2100

Impeller

2200

Casing

1100

Cover

1220

Adapter - Bearing Housing

1340

Shaft

2100

Impeller

2200

Casing

1100

Cover

1220

Adapter - Bearing Housing

1340

Shaft

2100

Impeller

2200

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Flowserve

Explore Other Assets