MaintainX, an Autodesk company
EnterprisePricing
Case

Case Tractor FARMALL JX 100 DT

Need answers fast?
Explore the manual using AI.

Case Tractor FARMALL JX 100 DT
Case Tractor FARMALL JX 100 DT

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Case Tractor FARMALL JX 100 DT

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Case Tractor FARMALL JX 100 DT

Case Tractor FARMALL JX 100 DT

Create an account to install this asset package.

Maintenance Plans for Case Tractor Model FARMALL JX 100 DT

Integrate maintenance plans directly into your work orders in MaintainX.

Refrigerant Leak Test

Check mark

Preparation

Check mark

Ensure the instrument is switched off before replacing the sensing tip.

Check mark

Remove the sensing tip by unscrewing it in a counter-clockwise direction.

Check mark

Fit a new tip and a new felt pad, screwing them in a clockwise direction onto the flexible probe.

Check mark

Check that there is no grease or dirt in the connecting hole between the probe and the tip.

Check mark

Initial Setup

Check mark

Start the engine.

Check mark

Set the ventilation fan to maximum speed.

Check mark

Turn knob (2, fig. 10) to switch on the air conditioner.

Run this procedureArrow right

Taper-Roller Bearing Adjustment

Check mark

Bearing Mounting

Check mark

Mount the external track of the bearing with the calculated adjuster shim (S) and the bevel pinion complete with its parts.

Check mark

Bearing Adjustment

Check mark

Tighten the bearing adjustment nut while turning the pinion shaft until rolling torque of 0.73--1.47 Nm (1.1063--1.4751 ft lb) is obtained.

Check mark

Torque Measurement

Check mark

Mesh the range selecting sleeve with the slow range gear.

Check mark

Measure the rolling torque with a torque meter and a cord wound around the slow range gear of the pinion. Ensure the torque corresponds to a force of 8.63 -- 17.2 N (1.9409 -- 3.8598 lb).

Check mark

Final Adjustment

Check mark

Bend the securing thrust washer onto the adjuster nut to prevent it from unscrewing and decreasing the bearing pre-load.

Run this procedureArrow right

Receiver - Drier Replacement

Check mark

Safety Instructions

Check mark

Adhere to the safety instructions on page 2 when recovering the refrigerant from the system.

Check mark

Refrigerant Recovery

Check mark

Recover the refrigerant from the system using station 294048 as described on page 22.

Check mark

Preparation

Check mark

Detach the exhaust pipe and raise the hood.

Check mark

Disconnect the negative battery lead.

Check mark

Disconnection

Check mark

Disconnect the electrical connector (1) from the receiver--drier.

Run this procedureArrow right

Starter Motor Earth Check

Check mark

Pre-test Checks

Check mark

Check the battery is fully charged

Check mark

Inspect for broken or frayed wires in the starting system

Check mark

Ensure there are no loose connections

Check mark

Verify the engine is not seized

Check mark

Voltmeter Connection

Check mark

Connect the positive voltmeter point to the starter motor casing

Check mark

Connect the negative voltmeter point to the engine block

Check mark

Testing and Results

Run this procedureArrow right

Battery Maintenance

Check mark

WARNING: Batteries contain sulphuric acid and generate a highly explosive hydrogen and oxygen mix during charging.

Check mark

Safety Precautions

Check mark

Do not use devices producing flames or sparks to inspect the electrolyte level.

Check mark

Do not remove battery caps without protecting your hands and your eyes.

Check mark

Electrolyte Level Maintenance

Check mark

Ensure the electrolyte level is 17 mm (0.6993 in.) over the plates.

Check mark

Is the electrolyte level maintained at 17 mm (0.6993 in.) over the plates?

Check mark

Water Usage

Check mark

Use only the following types of water

Run this procedureArrow right

Parts for Case Tractor FARMALL JX 100 DT

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Tractor Dismantling Stand

380000236

Engine Lifting Hook

380000216

Rotating Engine Service Stand

380000301

Engine Mounting Brackets (For Rotating Stand 380000301)

380000313

Compression Test Kit (Complete With Dummy Injector 380000617)

380000303

Tractor Dismantling Stand

380000236

Engine Lifting Hook

380000216

Rotating Engine Service Stand

380000301

Engine Mounting Brackets (For Rotating Stand 380000301)

380000313

Compression Test Kit (Complete With Dummy Injector 380000617)

380000303

Tractor Dismantling Stand

380000236

Engine Lifting Hook

380000216

Rotating Engine Service Stand

380000301

Engine Mounting Brackets (For Rotating Stand 380000301)

380000313

Compression Test Kit (Complete With Dummy Injector 380000617)

380000303

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Case

Explore Other Assets