Aerzen Blower GM35S
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
4000 Hourly / 6 Monthly Lube Oil Change
Preparation
Ensure the equipment has been operating for at least 4,000 hours or 6 months since the last oil change.
Is the discharge temperature over 140 °C?
Oil Draining and Filling
Follow the full oil draining and filling procedure as described in Initial 500 Hours Lube Oil Change.
Personnel
Ensure service personnel are available for the procedure.
4000 Hourly / 6 Monthly Belts Inspection
General Instructions
Review relevant chapters
Ensure personnel are service personnel
Check the condition of the belts and replace if necessary
Version with Lifting Device
Lift the hinged motor support using the hinge jig
Turn guide bushing (pos.3) anti-clockwise using the ratchet wrench
Raise the hinged motor support until the belts are fully relieved of tension
Replace belts as a set
Initial 500 Hours Starting Strainer Check
Maintenance schedule for normal operation
Determine the resistance (pressure loss) of the starting strainer
Is the resistance within the maximum limit of 45-50 mbar?
Ensure the inside of the pipe is clean
Removal and replacement
Did the resistance increase during the first 500 operating hours?
Is the starting strainer clean?
Remove the starting strainer and replace it with the provided adjusting ring
Removal and cleaning
8000 Hourly / 12 Monthly Lube Oil Change
8.2.1 Maintenance schedule for normal operation
Maintenance interval
Reference Chapter 8.3.5 'Changing oil' on page 150
Replace the lube oil
Personnel involved
Follow the full oil draining and filling procedure as described in Initial 500 Hours Lube Oil Change
Initial 3 Hours Blower Check
Performing checks after commissioning — After the first 3 operating hours
Check that all components are in place and functioning
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX