Aaon Horizontal Indoor Air Handling Units H3 Series
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly E-Coated Coil Cleaning
WARNING: Electric shock hazard. Shut off all electrical power to the unit to avoid shock hazard or injury from rotating parts.
Surface loaded fibers or dirt must be removed prior to water rinse to prevent restriction of airflow.
Surface loaded fibers or dirt removed with a vacuum cleaner or a soft non-metallic bristle brush?
Use of a water stream, such as a garden hose, against a surface loaded coil will drive the fibers and dirt into the coil.
Surface loaded fibers completely removed prior to using low velocity clean water rinse?
CAUTION: High velocity water from a pressure washer or compressed air should only be used at a very low pressure to prevent fin and/or coil damages.
Quarterly cleaning is essential to extend the life of an e-coated coil and is required to maintain coating warranty coverage.
CAUTION: Harsh chemicals, household bleach, or acid cleaners should not be used to clean outdoor or indoor e-coated coils.
For routine quarterly cleaning, first clean the coil with the below approved coil cleaner.
1 Monthly Filter Replacement
WARNING: Electric shock hazard. Shut off all electrical power to the unit to avoid shock hazard or injury from rotating parts.
Check if the power is off.
It is strongly recommended that filter media be replaced monthly.
Inspect filters located upstream of the evaporator coil.
Open access panel and pull filters straight out to inspect all of the filters.
Enter the size indicated on each filter.
Check if the arrow on the replacement filters points towards the blower.
Units with an energy recovery wheel with have additional filters.
Check the Filter replacement section under the energy recover wheel section for more information.
1 Monthly Horizontal Indoor Air Handling Unit Maintenance
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer. A copy of this IOM must be kept with the unit.
Inspect supply fans.
Inspect evaporator coils.
Inspect air filters.
Check the air flow.
Check the air filters.
Check condenser water flow.
Check refrigerant charge.
See Startup section for information on air flow adjustment and refrigerant charge adjustment.
1 Yearly Energy Recovery Wheel General Cleaning
Routine maintenance of the Energy Recovery
Wheel includes periodic cleaning of the Energy Recovery Wheel as well as inspection of the Air Seals and Wheel Drive Components.
CAUTION: Disconnect electrical power before servicing energy recovery cassette. Always keep hands away from bearing support beam when installing or removing segments. Failure to do so could result in severe injury to fingers or hand.
Cleaning the energy transfer media will help maintain optimal performance. The frequency of cleaning is largely dependent on the application and air quality. Use ASHRAE’s Classes of Air categories, to create a routine cleaning schedule.
Class 1 air has low contaminant concentration with inoffensive odor and sensory irritation intensity.
Class 2 air has moderate contaminant concentration, with mildly offensive odors or sensory-irritation intensity.
Class 3 air has significant contaminant concentration and significant offensive odor or sensory-irritation intensity.
Class 4 air has highly objectionable fumes or gases and potentially contains dangerous particles, bio-aerosols, or gases at a concentration high enough to be considered harmful, not suitable for recirculation or transfer to any other space.
Every 1-2 years Clean Dirty Air:
1 Yearly Leak Test
DANGER: LEAK CHECK GAS PIPE
CAUTION: Some soaps used for leak detection can be corrosive to certain metals. Rinse piping thoroughly after leak test has been completed.
WARNING: Gas pressure to appliance controls must never exceed 14” w.c. (1/2 psi)
Manual shut off valves checked for leaks
Piping in the interior of the unit checked for leaks
All gas piping connections checked for leaks
Enter the gas pressure to appliance controls
Was pressure testing at 1/2 psi or less performed?
Was pressure testing gas supply line at 1/2 psi or higher performed?
Access the parts list for your equipment in MaintainX.
Enviro-Coil Cleaner
V82540
GulfClean Salt ReducerTM
G074490
GulfClean TM Coil Cleaner
G074480
Enviro-Coil Cleaner
V82540
GulfClean Salt ReducerTM
G074490
GulfClean TM Coil Cleaner
G074480
Enviro-Coil Cleaner
V82540
GulfClean Salt ReducerTM
G074490
GulfClean TM Coil Cleaner
G074480
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX