

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Rooftop Unit ZH150E54B5B5BCA2A1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Smoke Detector Cleaning
Pre-Cleaning Inspection
Ensure power to the smoke detector is turned off
Inspect the smoke detector for any visible damage
Cleaning Process
Remove the smoke detector cover
Clean the smoke detector using a soft brush or vacuum cleaner
Reattach the smoke detector cover
Post-Cleaning Testing
Restore power to the smoke detector
Supply Air Drive Adjustment
Supply Air Drive Adjustment
Pre-Adjustment Caution
Review the installation for any errors, leaks, or undesirable system effects.
Ensure only qualified personnel are making blower speed changes.
Blower Speed Adjustment
Enter the required CFM.
Enter the measured CFM.
Enter the existing datum diameter (DD) of the motor sheave.
Calculate the new datum diameter (DD) using the formula: Required CFM / Measured CFM × Existing DD = New DD.
Rooftop Unit Start-up Check
Prestart Check List
Check the electrical supply voltage being supplied
Set the room thermostat to the off position
Turn unit electrical power on
Set the room thermostat fan switch to on
Check indoor blower rotation
Check blower drive belt tension
Check the unit supply air (CFM)
Measure evaporator fan motor's amp draw
Belt Tension Adjustment
Pre-Adjustment Check
Is the unit equipped with power exhaust fans or a return air fan?
Belt Tension Adjustment Procedure
Loosen the four bolts holding the motor base to the channels
Adjust the belt by turning nuts 'A' (see detail 'B')
Apply a perpendicular force to one belt at the midpoint of the span using a belt tension checker
Enter the deflection distance obtained (in inches)
Use a straight edge from sheave to sheave as a reference line to determine the deflection distance from the normal position
Check the belt tension at least two times during the first 24 hours of operation
Air Quantity Check
Method One
Remove the dot plugs from the duct panel
Insert eight inches of 1/4 inch metal tubing into the airflow on both sides of the indoor coil
Ensure tubes are perpendicular to the airflow
Deactivate compressors before taking measurements
Determine the pressure drop across a dry evaporator coil using an Inclined Manometer or Magnehelic
Ensure air filters are clean for accurate measurement
Determine the CFM through the unit from the pressure drop indicated by the manometer
Adjust Measured CFM to Required CFM using SUPPLY AIR DRIVE ADJUSTMENT
Access the parts list for your equipment in MaintainX.
Optional Co2 Space Sensor Kit
2AQ04700524
Optional Co2 Sensor Kit
2AQ04700624
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Non-Plenum Application Anixter
CBL-22/3-FC-PVC
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Non-Plenum Application Belden
B5501FE
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Plenum Application Anixter
CBL-22/3-FC-PLN
Optional Co2 Space Sensor Kit
2AQ04700524
Optional Co2 Sensor Kit
2AQ04700624
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Non-Plenum Application Anixter
CBL-22/3-FC-PVC
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Non-Plenum Application Belden
B5501FE
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Plenum Application Anixter
CBL-22/3-FC-PLN
Optional Co2 Space Sensor Kit
2AQ04700524
Optional Co2 Sensor Kit
2AQ04700624
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Non-Plenum Application Anixter
CBL-22/3-FC-PVC
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Non-Plenum Application Belden
B5501FE
Fc Bus 22 Awg Stranded 3-Wire Twisted Shielded Cable Plenum Application Anixter
CBL-22/3-FC-PLN
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













