MaintainX Asset Hub logo
EnterprisePricing
Baldor Reliance

Baldor Reliance Electric Motor EM3714T

Need answers fast?
Explore the manual using AI.

Baldor Reliance Electric Motor EM3714T
Baldor Reliance Electric Motor EM3714T

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Baldor Reliance Electric Motor EM3714T

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Baldor Reliance Electric Motor EM3714T

Baldor Reliance Electric Motor EM3714T

Create an account to install this asset package.

Maintenance Plans for Baldor Reliance Electric Motor Model EM3714T

Integrate maintenance plans directly into your work orders in MaintainX.

1 Monthly Sleeve Bearing Maintenance

Check mark

Storage

Check mark

Ensure sleeve bearing (oil lube) motors are drained of oil prior to shipment

Check mark

Refill oil reservoirs to the indicated level with the specified lubricant

Check mark

Rotate the shaft by hand for 10 to 15 revolutions to distribute oil to bearing surfaces

Run this procedureArrow right

500 Hourly / 3 Monthly Motor Periodic Inspection

Check mark

Section 3 — Periodic Inspection

Check mark

Listen for any abnormal noises and check cause immediately

Check mark

Check for any vibration and check cause immediately if excessive vibration is found

Check mark

Check voltage and frequency variations

Check mark

Check power supply total harmonic distortion

Check mark

Periodic checks of phase, voltage, frequency, and power consumption

Check mark

Check air filters and air passages

Check mark

Check for proper lubrication

Check mark

Check that constant level oilers have oil in them and cap is screwed on tightly

Run this procedureArrow right

6 Monthly Motor Maintenance

Check mark

Section 3 — Semi-Annual Maintenance

Check mark

Inspect and clean components

Check mark

Check electrical connections

Run this procedureArrow right

3 Monthly Anti-Friction Bearing Re-Lubrication

Check mark

Section 3 — Lubrication Procedure

Check mark

Ensure lubrication is done with motor running, stay clear of rotating parts and electrical circuits

Check mark

Avoid over-lubrication of motor

Check mark

Relubricate with the shaft stationary and a warm motor

Check mark

Locate the grease inlet, clean the area and replace the pipe plug with a grease fitting if necessary

Check mark

Remove relief plug

Check mark

Clean caked grease around the plug with a wooden stick or suitable tool

Check mark

If severe caking appears, run the motor until the bearing housing is warm

Check mark

Locate the motor nameplate and find the recommended lubricant type and volume

Run this procedureArrow right

6 Monthly Anti-Friction Bearing Re-Lubrication

Check mark

Standard Conditions: 8 hours per day of operation, ambient temperature maximum 40°C, clean with little corrosion

Check mark

For motors running 1800 RPM and slower under standard conditions, use the 1 Yearly task instead

Check mark

For roller bearings, divide the relubrication interval by 2 (maintenance required more frequently)

Check mark

Severe Conditions: 16 plus hours per day of operation, ambient temperature maximum 50°C, moderate dirt and corrosion

Check mark

This interval applies to motors 1 thru 7-1/2 HP running at 1800 RPM or less

Check mark

For roller bearings, divide the relubrication interval by 2 (maintenance required more frequently)

Check mark

SECTION: Section 3 — Recommended Lubricant

Check mark

Refer to motor nameplate

Check mark

Use only clean, fresh grease from clean containers

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Baldor Reliance

Explore Other Assets