

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Atlas Copco Oxygen Generator OGP 8
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Oxygen Sensor Calibration
Safety Precautions and Initial Setup
Ensure the following valves are closed
Confirm machine working pressure is 0 bar
Switch off the generator
Is the generator fully depressurized and purged with air?
Vent oxygen to the outside atmosphere
Ensure no smoking or open flames near the oxygen generator
Calibration Check
Set the generator in Manual mode
6 Monthly Vessel Inspection
Pre-Inspection Safety Precautions
Close the generator's outlet valve and the air inlet valve
Ensure machine working pressure is 0 bar
Switch off the generator
Ensure generator is fully depressurized
Purge thoroughly with air to remove all oxygen
Vent oxygen to the outside atmosphere
Ensure no smoking or open flames in the vicinity of the oxygen generator
Avoid closing valves too fast to prevent high gas velocities
5 Yearly Oxygen Sensor Replacement
Safety Precautions
Close the generator's outlet valve and the air inlet valve
Wait until machine working pressure is 0 bar
Switch off the generator
Ensure the generator is fully depressurized and purge thoroughly with air
Vent oxygen to the outside atmosphere
Prohibit smoking and use of open flames near the oxygen generator
Avoid closing valves too fast to prevent hazardous gas velocities
Preparation
16000 Hourly/2 Yearly Oxygen Generator Maintenance
Read safety recommendations and precautions
Close the generator's outlet valve and the air inlet valve
Wait until machine working pressure is 0 bar
Switch off the generator
Ensure the generator is fully depressurized and purge thoroughly with air
Vent oxygen to the outside atmosphere
Check for damaged wiring or loose connections
Check for air leaks
Replace the in- and outlet filter cartridges
8000 Hourly/1 Yearly Oxygen Generator Maintenance
Read recommendations and safety precautions
Close the generator's outlet valve and the air inlet valve
Wait until machine working pressure is 0 bar
Switch off the generator
Ensure the generator is fully depressurized and purge thoroughly with air
Vent oxygen to the outside atmosphere
Check for damaged wiring or loose connections
Check for air leaks
Replace the in- and outlet filter cartridges
Access the parts list for your equipment in MaintainX.
Flow Sensor
CS VA420
Vessel
BF150PED11L
Flow Sensor
CS VA420
Vessel
BF150PED11L
Flow Sensor
CS VA420
Vessel
BF150PED11L
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













