Atlas Copco Oxygen Generator OGP 14
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
6 Monthly Vessel Inspection
Pre-Inspection Safety Precautions
Close the generator's outlet valve and the air inlet valve
Ensure machine working pressure is 0 bar
Switch off the generator
Is the generator fully depressurized and purged with air?
Vent oxygen to the outside atmosphere
Ensure no smoking or open flames are present near the oxygen generator
Inspection Steps
Visual check of the vessel (tank) material for traces of strong corrosion
1 Yearly Oxygen Sensor Calibration
Safety Precautions and Initial Setup
Close the generator's outlet valve and the air inlet valve and wait until machine working pressure is 0 bar.
Switch off the generator.
Ensure the generator is fully depressurized and purge thoroughly with air to remove all oxygen before service or inspection.
Vent oxygen to the outside atmosphere.
Ensure no smoking or open flames are in the vicinity of the oxygen generator.
Avoid closing valves too fast to prevent high gas velocities.
Calibration Check
Set the generator in Manual mode (Operation Mode).
Flow Sensor Adjustment
Introduction
Check the flow sensor model compatibility
Verify installation location
Measure the flow rate consumption
Is the flow rate within the expected range?
Adjust the flow sensor settings if necessary
Overview of model versus flow sensor
Confirm the correct flow sensor is used for the model
1 Daily Controller Check
Safety Precautions
Close the generator's outlet valve and the air inlet valve
Ensure machine working pressure is 0 bar
Switch off the generator
Is the generator fully depressurized and purged with air?
Vent oxygen to the outside atmosphere
Ensure no smoking or open flames are present near the oxygen generator
Avoid closing valves too fast to prevent hazardous gas velocities
Controller Check
16000 Hourly/2 Yearly Oxygen Generator Maintenance
Read safety recommendations and precautions
Close the generator's outlet valve and the air inlet valve
Wait until machine working pressure is 0 bar
Switch off the generator
Ensure the generator is fully depressurized and purge thoroughly with air
Vent oxygen to the outside atmosphere
Check for damaged wiring or loose connections
Check for air leaks
Replace the in- and outlet filter cartridges
Access the parts list for your equipment in MaintainX.
Flow Sensor
CS VA420
Vessel
BF280PED11L
Flow Sensor
CS VA420
Vessel
BF280PED11L
Flow Sensor
CS VA420
Vessel
BF280PED11L
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX