Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Telsmith Vibrating Aggregate Screen 6 x 20 Single Deck
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1500 Hourly / 6 Monthly Bearing Housing Breather Maintenance
Breather Assembly Removal
Remove the breather assembly from the top of the bearing housing by unthreading the complete assembly at the threaded bushing.
Breather Assembly Cleaning
Separate the breather cover from the mounting bushing by unscrewing the cover from the bushing.
Clean the assembly with solvent.
Blow dry the assembly with compressed air.
Breather Replacement
Were blockages removed successfully?
Replace the breather with a new unit if blockages cannot be removed.
1 Daily Vibrating Aggregate Screen Check
Wire Cloth Screen Inspection
Check wire weave for breaks, tears or separation of the wire.
Replace wire that exhibits any damage.
Operating Screen Observation
Are there any panels with 'dead spots' where material is puddling?
Replace wire panels that no longer maintain tension over the complete surface area.
Screen Tension and Buffer Check
Is the screen tight against all buffer and crown bars?
Replace rubber if missing, torn or worn through to the metal on crown bars.
Wire Support Frame Replacement
Preparation
Ensure cross bracing is provided if all support frames and drive unit/shaft casings are removed.
Determine sequence of wire support frame removal based on screen model and drive unit/shaft casing status.
Wire Support Frame Removal
Remove all cross braces from the bottom side of the screen frame.
Support the back plate with a hoist and lift straps, then remove and lower it.
Support the discharge lip with straps and a hoist, then remove and lower it.
Support the wire frame from above with lift straps at all four corners.
Cut the huck bolts at the four corners and temporarily replace them with bolts, nuts, and washers.
Vibrating Aggregate Screen Counterweight Shim Replacement
Preparation
Consult Telsmith Engineering Department before proceeding with shim changes
Shim Removal
Remove the two hex head capscrews holding the counterweight shim stack
Slide the shims out one at a time off the counterweight hub
Shim Installation
Slide additional shims on the counterweight hub if required
Fasten shims in position with the two hex head capscrews
Safety Check
1 Weekly Vibrating Aggregate Screen Maintenance
Vibrator and Sheave Inspection
Check vibrator oil for impurities (oil sample)
Check nuts and bolts for tightness or missing fasteners
Check decks for heavily worn hardware or worn cross members
Check that vibrating unit drive sheave is free of debris and tight on shaft bushing
Check that electric drive motor output sheave is tight on shaft
Component Inspection and Replacement
Inspect friction pucks. Replace if surface is worn below usable dimension
Check live frame for cracks or broken welds
Access the parts list for your equipment in MaintainX.
Drive Guard - Back
1045975
Drive Guard Mount - Lower
1045979
Drive Guard Mount - Upper
1045978
Drive Guard - Front Cover Yellow
1045976
Drive Guard - Front Cover Yellow
1045977
Drive Guard - Back
1045975
Drive Guard Mount - Lower
1045979
Drive Guard Mount - Upper
1045978
Drive Guard - Front Cover Yellow
1045976
Drive Guard - Front Cover Yellow
1045977
Drive Guard - Back
1045975
Drive Guard Mount - Lower
1045979
Drive Guard Mount - Upper
1045978
Drive Guard - Front Cover Yellow
1045976
Drive Guard - Front Cover Yellow
1045977
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX