

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Ohaus Moisture Analyzer MB27
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Temperature Calibration
Preparation
Remove the Pan Support for the temperature calibration to start.
Place the OHAUS Temperature Calibration Kit into the temperature chamber and close the cover.
Calibration Process
Press and hold Cal until “Cal” is displayed. Release when “TC100” appears and the heater turns on.
Wait for 15 minutes until the unit beeps and blinks “100” on the display.
Read the thermometer on the Temperature Calibration Kit.
Press Set to change and match the displayed value to the thermometer reading.
Press Tare to enter the value. Confirm that the display shows “TC160” as the heater turns on again.
Moisture Analyzer Cleaning
Preparation
Disconnect the Analyzer from the power supply
Ensure the Analyzer is cooled down before cleaning
Cleaning Process
Ensure no liquid enters the interior of the Analyzer
Clean housing surfaces and temperature sensor with a lint-free cloth dampened with water or mild cleaning agent
Clean glass surfaces with a commercial glass cleaner
Prohibited Actions
Avoid using the following during cleaning
Weight Calibration
Preparation
Remove any load on the Pan Support including the sample pan
Calibration Process
Press and hold Cal while in the Weigh mode until “CAL” appears followed by “50.00g”
Place a 50g calibration mass on the Pan Support when prompted
Remove the mass when “--0--” is shown on the display
Did the Analyzer return to Weigh mode indicating calibration completion?
Cancellation
Was START pressed to cancel the calibration without saving changes?
Access the parts list for your equipment in MaintainX.
Anti Theft Device
80850043
Temp Calibration Kit
11113857
In Use Cover
80252475
Sample Pan Handler
80252476
Reusable Wire Cage
80252477
Anti Theft Device
80850043
Temp Calibration Kit
11113857
In Use Cover
80252475
Sample Pan Handler
80252476
Reusable Wire Cage
80252477
Anti Theft Device
80850043
Temp Calibration Kit
11113857
In Use Cover
80252475
Sample Pan Handler
80252476
Reusable Wire Cage
80252477
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













