MaintainX Asset Hub logo
EnterprisePricing
The New York Blower Company

The New York Blower Company Blower AF-60

Need answers fast?
Explore the manual using AI.

The New York Blower Company Blower AF-60
The New York Blower Company Blower AF-60

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for The New York Blower Company Blower AF-60

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

The New York Blower Company Blower AF-60

The New York Blower Company Blower AF-60

Create an account to install this asset package.

Maintenance Plans for The New York Blower Company Blower Model AF-60

Integrate maintenance plans directly into your work orders in MaintainX.

Fan Wheel Inspection

Check mark

Fan Maintenance

Check mark

Ensure electrical supply is completely disconnected and locked out

Check mark

Block the rotating assembly securely

Check mark

Inspect the fan wheel for issues

Check mark

Is there any wear or corrosion on the fan wheel?

Check mark

Is there any build-up of material on the fan wheel?

Check mark

Clean or replace the fan wheel as required

Check mark

Ensure the fan hub is not removed or loosened from the fan wheel

Run this procedureArrow right

Coupling Maintenance

Check mark

COUPLING — Alignment

Check mark

Lubricate the coupling of direct-drive units and check for alignment

Check mark

Refer to manufacturer's installation and maintenance supplement for lubrication details and alignment tolerances

Check mark

Recheck alignment and gap after a short period of operation

Check mark

Recheck the tightness of all fasteners in the coupling assembly

Check mark

Check coupling alignment after permanent installation and prior to start up

Check mark

Align the coupling to within the manufacturer's limits for parallel and angular misalignment

Check mark

Post Maintenance Review

Check mark

Was the coupling alignment within the manufacturer's specified limits?

Run this procedureArrow right

V-Belt Drive Inspection

Check mark

FAN MAINTENANCE / V-BELT DRIVE

Check mark

Ensure electrical supply is disconnected and locked out

Check mark

Check the V-belt drive for proper alignment and tension

Check mark

Check belt tension with a tensioning gage

Check mark

Adjust belt tension using the motor slide base

Check mark

Replace worn belts as a set, matched to manufacturer's tolerances

Check mark

Check sheave alignment with a straightedge

Check mark

Check setscrew and/or bushing bolt tightness

Run this procedureArrow right

Fan Bolts Tightness Inspection

Check mark

Fan Maintenance

Check mark

Ensure electrical supply is disconnected and locked out

Check mark

Check all setscrews and bolts for tightness

Check mark

Refer to the corresponding table for correct torques

Check mark

Recheck all wheel, sheave, and coupling setscrews after specified operation times

Check mark

Refer to Table 1 for wheel setscrew torques

Check mark

Refer to Table 2 for bearing setscrew torques

Check mark

Shut down the fan if there is any sudden increase in fan vibration

Run this procedureArrow right

Initial V-Belt Tension Check

Check mark

V-BELT DRIVE — Belt Tensioning

Check mark

Verify the following components

Check mark

Has the belt tension been rechecked after several days of operation?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from The New York Blower Company

Explore Other Assets