

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Lochinvar Boiler WHB285L
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Condensate Trap Inspection
Safety Precautions
Ensure the boiler is not frozen. If frozen, shut off power and gas immediately and contact the factory.
Turn off power to the boiler before starting inspection.
Condensate Trap Inspection
Check that the condensate trap is properly installed and connected to the condensate pipe under the boiler.
Inspect the condensate line for obstructions to ensure free flow of condensate.
Inspect the neutralizing kit (if installed) to ensure proper drainage and adequate neutralizing agent.
Post Inspection
Turn the power back on to the boiler after inspection is complete.
1 Yearly Condensate Trap Cleaning
Safety Precautions
Shut off power and gas to the appliance if the boiler may be frozen
Ensure the boiler is inspected by a qualified service technician
Turn off power to the boiler before any service operation
Condensate Trap Cleaning
Remove the bottom cap of the condensate trap
Clean out any sediment from the condensate trap
Condensate Trap Inspection
Check that the ball is present in the condensate trap
1 Yearly Relief Valve Maintenance
Safety Precautions
Ensure the boiler is not frozen
Shut off power and gas to the appliance if frozen
Contact the factory for further instructions if frozen
Turn off power to the boiler before any service operation
Inspection and Operation
Check that a discharge line is connected to the relief valve
Operate the valve lever to ensure waterways are clear
Check for water discharge when operating the valve lever
Ignition Ground Wiring Check
Safety Precautions
Ensure the boiler is not frozen
Shut off power and gas to the appliance if frozen
Contact the factory for further instructions if frozen
Turn off power to the boiler before any service operation
Inspect boiler ground wire from the heat exchanger access cover to ground terminal strip
Verify all wiring is in good condition and securely attached
Check ground continuity of wiring using continuity meter
Replace ground wires if ground continuity is not satisfactory
Boiler Interior Inspection
Safety Precautions
Ensure the boiler is not frozen
Shut off power and gas to the appliance if frozen
Contact the factory for further instructions if frozen
Turn off power to the boiler before any service operation
Inspection and Cleaning
Remove the front access cover
Inspect the interior of the boiler
Vacuum any sediment from inside the boiler and components
Access the parts list for your equipment in MaintainX.
Vent Kit, Lochinvar, 2 Inch
100157609
Vent Kit, Lochinvar, 3 Inch
100157610
Vent Kit, Lochinvar, 4 Inch
100157611
Vent Kit, Centrotherm, 2 Inch
ISLPT0202
Vent Kit, Centrotherm, 3 Inch
ISLPT0303
Vent Kit, Lochinvar, 2 Inch
100157609
Vent Kit, Lochinvar, 3 Inch
100157610
Vent Kit, Lochinvar, 4 Inch
100157611
Vent Kit, Centrotherm, 2 Inch
ISLPT0202
Vent Kit, Centrotherm, 3 Inch
ISLPT0303
Vent Kit, Lochinvar, 2 Inch
100157609
Vent Kit, Lochinvar, 3 Inch
100157610
Vent Kit, Lochinvar, 4 Inch
100157611
Vent Kit, Centrotherm, 2 Inch
ISLPT0202
Vent Kit, Centrotherm, 3 Inch
ISLPT0303
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













