MaintainX Asset Hub logo
EnterprisePricing
Leybold

Leybold Vacuum Pump SP250 115 004

Need answers fast?
Explore the manual using AI.

Leybold Vacuum Pump SP250 115 004
Leybold Vacuum Pump SP250 115 004

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Leybold Vacuum Pump SP250 115 004

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Leybold Vacuum Pump SP250 115 004

Leybold Vacuum Pump SP250 115 004

Create an account to install this asset package.

Maintenance Plans for Leybold Vacuum Pump Model SP250 115 004

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Gas Ballast Air Filter Cleaning

Check mark

2.9.1.1 Maintenance on the Air Filter

Check mark

Ensure all necessary tools and safety equipment are available

Check mark

Open the locking clips at the air filter and remove the dust cap

Check mark

Apply an open jaw spanner to the hexagon and unscrew the filter element

Check mark

Blow out the filter element from the threaded side with dry compressed air

Check mark

Re-seal the thread with Teflon tape and refit the filter element

Check mark

Fit the dust cap again and affix it with the locking clips

Check mark

Fit the cover in the reverse order as described in Chapter 2.4.1

Check mark

Solenoid Gas Ballast Valve Version

Run this procedureArrow right

Pump Oil Level Check

Check mark

3.1 Checking the Oil Level

Check mark

Ensure the pump and oil have cooled down

Check mark

Wear protective gloves and goggles

Check mark

Check the oil level at the oil sight glass

Check mark

Is the oil level between the maximum and minimum mark?

Check mark

Top up oil if the level is at the minimum mark

Run this procedureArrow right

Pump Storage Maintenance

Check mark

1.8 Storing

Check mark

Run the pump dry for at least 30 minutes

Check mark

Seal off the flanges with desiccant and foil

Check mark

Drain out the oil before long-term storage

Check mark

Package the pump in polyethylene foil and seal it air-tight

Check mark

Ensure storage conditions are met

Run this procedureArrow right

6 Monthly Condensate Separator Maintenance

Check mark

3.3 Draining Out Condensate (optional)

Check mark

Separate the pump from the process by a valve

Check mark

Check the optional silencer (P/N 119 002) for condensate collection

Check mark

Is there liquid collected in the silencer?

Check mark

Drain the liquid from the silencer through the condensate drain

Check mark

Empty the condensate separator

Run this procedureArrow right

40000 Hourly / 2 Yearly Pump Inspection

Check mark

3.6 Table/Maintenance and Servicing Work ScrewLine SP 250

Check mark

Verify inspection requirements

Check mark

Ensure inspection is carried out by Leybold service

Check mark

Ensure rotor inspection by Leybold Vacuum Field Service

Check mark

Check availability of required spare parts

Run this procedureArrow right

Parts for Leybold Vacuum Pump SP250 115 004

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Exhaust Silencer With Condensate Drain

119 002

Non-Return Valve

119 011

Filter Adapter 65 ISO-K

119 019

Roots Pump Adapter For RUVAC 1001/501

119 022

Optional Exhaust Flange

119 023

Exhaust Silencer With Condensate Drain

119 002

Non-Return Valve

119 011

Filter Adapter 65 ISO-K

119 019

Roots Pump Adapter For RUVAC 1001/501

119 022

Optional Exhaust Flange

119 023

Exhaust Silencer With Condensate Drain

119 002

Non-Return Valve

119 011

Filter Adapter 65 ISO-K

119 019

Roots Pump Adapter For RUVAC 1001/501

119 022

Optional Exhaust Flange

119 023

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Leybold

Explore Other Assets