MaintainX Asset Hub logo
EnterprisePricing
Leybold

Leybold Vacuum Pump SP250 115 001

Need answers fast?
Explore the manual using AI.

Leybold Vacuum Pump SP250 115 001
Leybold Vacuum Pump SP250 115 001

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Leybold Vacuum Pump SP250 115 001

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Leybold Vacuum Pump SP250 115 001

Leybold Vacuum Pump SP250 115 001

Create an account to install this asset package.

Maintenance Plans for Leybold Vacuum Pump Model SP250 115 001

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Inlet Screen Cleaning

Check mark

2.4.4 Regular Checks

Check mark

Disconnect the intake line

Check mark

Remove the inlet screen from the intake port

Check mark

Clean the inlet screen in a suitable way

Check mark

Is the inlet screen defective?

Check mark

Replace the inlet screen if defective

Check mark

Are large amounts of abrasive materials present?

Check mark

Fit a suitable dust filter into the intake line if necessary

Run this procedureArrow right

6 Monthly Exhaust Silencer Inspection

Check mark

3.6 Table/Maintenance and Servicing Work ScrewLine SP 250

Check mark

Check the exhaust silencer components

Check mark

Empty the exhaust silencer

Check mark

Refer to Brief Instructions KA02487 for detailed guidance

Check mark

Is the pump fitted with the optional exhaust silencer with condensate drain (P/N 119 002)?

Run this procedureArrow right

6 Monthly Dust Filter Cleaning

Check mark

3.4 Cleaning the Dust Filter (optional)

Check mark

Check for contamination in the dust filter

Check mark

Clean the dust filter if contamination is found

Check mark

Reinstall the dust filter after cleaning

Run this procedureArrow right

40000 Hourly / 2 Yearly Pump Inspection

Check mark

3.6 Table/Maintenance and Servicing Work ScrewLine SP 250

Check mark

Verify inspection requirements

Check mark

Is the inspection being carried out by the Leybold service?

Check mark

Is the rotor inspection (opening of the pump chamber) being done by the Leybold Vacuum Field Service?

Check mark

Ensure availability of required spare parts: EK 1100000821

Run this procedureArrow right

1 Yearly Oil Change

Check mark

3.1.1 Oil Change and Oil Filter Change

Check mark

Ensure the pump and oil have cooled down below 70 °C

Check mark

Wear protective gear

Check mark

Place a 10-litre collecting vessel under the ScrewLine

Check mark

Disassemble the cover section on the exhaust side

Check mark

Unscrew the oil drain plug and oil fill plug to drain the oil

Check mark

Clean the sealing surface and screw in the oil drain plug with a perfect gasket

Check mark

Wipe off any oil residues on the housing

Check mark

3.1.1.1 Replacing the Oil Filter

Run this procedureArrow right

Parts for Leybold Vacuum Pump SP250 115 001

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Exhaust Silencer With Condensate Drain

119 002

Non-Return Valve

119 011

Filter Adapter 65 ISO-K

119 019

Roots Pump Adapter For RUVAC 1001/501

119 022

Optional Exhaust Flange

119 023

Exhaust Silencer With Condensate Drain

119 002

Non-Return Valve

119 011

Filter Adapter 65 ISO-K

119 019

Roots Pump Adapter For RUVAC 1001/501

119 022

Optional Exhaust Flange

119 023

Exhaust Silencer With Condensate Drain

119 002

Non-Return Valve

119 011

Filter Adapter 65 ISO-K

119 019

Roots Pump Adapter For RUVAC 1001/501

119 022

Optional Exhaust Flange

119 023

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Leybold

Explore Other Assets