Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Leybold Vacuum Pump RUVAC WA 1001 EU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Fan Cowl and the Cooling Fins Cleaning
5.4 Cleaning the Fan Cowl and the Cooling Fins
Safety Information
Check for contamination
Clean the fan cowl grid
Remove coarse dirt from fins
Dirt Trap Cleaning
5.5 Cleaning the Dirt Trap
Ensure all safety precautions from Section 5.1 are followed
Remove the intake line
Remove the dirt trap from the intake flange
Rinse the dirt trap using a suitable solvent
Thoroughly dry the dirt trap with compressed air
Is the dirt trap damaged?
Replace the dirt trap if damaged
Pumping Chamber Cleaning
5.6 Cleaning the Pumping Chamber
Ensure all safety precautions from Section 5.1 are observed
Remove the two connecting lines
Choose method to remove contaminants
Change the oil after cleaning
During cleaning, were the impellers turned only by hand?
Ensure loosened deposits do not remain in the pump
Check the pump by slowly turning the impellers by hand to ensure they move freely and without resistance
Was the Roots pump disassembled?
Pressure Balance Line Valve Cleaning
5.7 Cleaning the Valve of the Pressure Balance Line
Observe all safety information provided in Section 5.1
Remove the screws and take off the cover (12/1) with O-ring (12/2)
Take out the spring (12/4)
Remove the valve disk (12/6) with O-rings (12/5) and (12/7)
Check if the bushing (12/3) is damaged and replace if necessary
Clean all parts or replace them if necessary
Reassemble in the reverse sequence
Check the O-rings for leak-tightness and replace if found faulty
3000 Hourly Shaft Seal Housing Oil Change
5.3 Oil change/shaft seal housing
Observe all safety information provided in Section 5.1
Unscrew the oil-drain screw (10/3) under the shaft seal housing
Drain out the oil
Screw in the oil-drain screw using a gasket in perfect condition
Fill in fresh oil at the oiler (10/1)
Is the oil level for the shaft seal housing visible in the oiler?
Maximum level
Select the current state of the pump
Access the parts list for your equipment in MaintainX.
Shaft Seal Driver For WA/WAU 1001/2001
722 81028
Set Of Gaskets WA/WAU 1001
194 68
Oil Pressure Switches WA/WAU 1001/2001 Only
194 82
Oil Drain Facility M 16 X 1,5 With Straight Drain Coupling
190 02
Oil Drain Facility M 16 X 1,5 With Right-Angled Drain Coupling
200 14 271
Shaft Seal Driver For WA/WAU 1001/2001
722 81028
Set Of Gaskets WA/WAU 1001
194 68
Oil Pressure Switches WA/WAU 1001/2001 Only
194 82
Oil Drain Facility M 16 X 1,5 With Straight Drain Coupling
190 02
Oil Drain Facility M 16 X 1,5 With Right-Angled Drain Coupling
200 14 271
Shaft Seal Driver For WA/WAU 1001/2001
722 81028
Set Of Gaskets WA/WAU 1001
194 68
Oil Pressure Switches WA/WAU 1001/2001 Only
194 82
Oil Drain Facility M 16 X 1,5 With Straight Drain Coupling
190 02
Oil Drain Facility M 16 X 1,5 With Right-Angled Drain Coupling
200 14 271
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX