Leybold Vacuum Pump RUVAC WA 2001 EU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Initial 500 Hours Gear Box Oil Change
5.2 Oil Change/Gear Box
Ensure all safety precautions are observed
Use the oil-drain facility for safety and simplicity
Unscrew the oil-drain screws (11/2) or (11/1) and the oil-fill screw (11/4) to drain the oil
Clean the sealing surface and reinstall the oil-drain screw using a perfect condition gasket
Wipe off any oil residues from the casing
Fill in new oil
Consult Sections 1.3 and 1.4 for oil quantities and ordering data
Ensure correct oil type is used
Gear Box Oil Level Check
Operation
Check the oil level in the oil level glass and the oiler
Is the oil level correct according to Section 5.2 and 5.3?
Check the condition of the oil
Is the oil condition acceptable?
Oil level — gear box
Check the oil level at vertical flow when the pump is not running
Check the oil level at horizontal flow
Is the oil level at the correct position for vertical flow?
Fan Cowl and the Cooling Fins Cleaning
5.4 Cleaning the Fan Cowl and the Cooling Fins
Safety Information
Inspect the fan cowl and cooling fins
Clean the fan cowl grid
Remove coarse dirt from the fins
Dirt Trap Cleaning
5.5 Cleaning the Dirt Trap
Observe all safety information provided in Section 5.1
Take off the intake line
Remove the dirt trap from the intake flange
Rinse the dirt trap using a suitable solvent
Thoroughly dry the dirt trap with compressed air
Is the dirt trap damaged?
Replace the dirt trap if it is damaged
Pressure Balance Line Valve Cleaning
5.7 Cleaning the Valve of the Pressure Balance Line
Observe all safety information provided in Section 5.1
Remove the screws and take off the cover (12/1) with O-ring (12/2)
Take out the spring (12/4)
Remove the valve disk (12/6) with O-rings (12/5) and (12/7)
Check if the bushing (12/3) is damaged and replace if necessary
Clean all parts or replace them if necessary
Reassemble in the reverse sequence
Check the O-rings for leak-tightness and replace if found faulty
Access the parts list for your equipment in MaintainX.
Shaft Seal Driver For WA/WAU 1001/2001
722 81028
Set Of Gaskets WA/WAU 2001
194 72
Oil Pressure Switches WA/WAU 1001/2001 Only
194 82
Oil Drain Facility M 16 X 1,5 With Straight Drain Coupling
190 02
Oil Drain Facility M 16 X 1,5 With Right-Angled Drain Coupling
200 14 271
Shaft Seal Driver For WA/WAU 1001/2001
722 81028
Set Of Gaskets WA/WAU 2001
194 72
Oil Pressure Switches WA/WAU 1001/2001 Only
194 82
Oil Drain Facility M 16 X 1,5 With Straight Drain Coupling
190 02
Oil Drain Facility M 16 X 1,5 With Right-Angled Drain Coupling
200 14 271
Shaft Seal Driver For WA/WAU 1001/2001
722 81028
Set Of Gaskets WA/WAU 2001
194 72
Oil Pressure Switches WA/WAU 1001/2001 Only
194 82
Oil Drain Facility M 16 X 1,5 With Straight Drain Coupling
190 02
Oil Drain Facility M 16 X 1,5 With Right-Angled Drain Coupling
200 14 271
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX