Manual for Contec Medical Systems Patient Monitor CMS9000

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Contec Medical Systems Patient Monitor CMS9000

Contec Medical Systems Patient Monitor CMS9000

Create an account to install this asset package.

Maintenance Plans for Contec Medical Systems Patient Monitor Model CMS9000

Integrate maintenance plans directly into your work orders in MaintainX.

2 Yearly Patient Monitor Check

Check mark

Pre-maintenance Preparation

Check mark

Clean the device

Check mark

Disinfect the device

Check mark

NIBP Checks

Check mark

Perform NIBP air leakage check

Check mark

Record NIBP pressure reading

Check mark

Perform NIBP calibration

Check mark

Perform TEMP calibration

Check mark

Perform CO check

Run this procedureArrow right

NIBP Cuff Cleaning

Check mark

Cuff Cleaning

Check mark

Take out the gasbag before cleaning.

Check mark

Select the cleaning method for the cuff

Check mark

Use a new cloth or paper towel with tap-water to wipe residual detergent until no obvious dirt remains.

Check mark

Use a dry soft cloth to wipe the residual water.

Check mark

Place the cuff in a ventilated and shady environment for air drying.

Check mark

Gasbag Replacement

Check mark

Roll up the gasbag lengthwise and place it into the cuff from the big opening side.

Check mark

Thread the leather hose of the airbag from the small hole on the cuff, from inside to outside.

Run this procedureArrow right

Host Cleaning

Check mark

Preparation

Check mark

Turn off the power and unplug the power cord

Check mark

Cleaning Process

Check mark

Use a soft cloth with proper detergent to wipe the external surface

Check mark

Use a new cloth or paper towel with tap water to remove residual detergent

Check mark

Post-Cleaning

Check mark

Place the device in a ventilated and shady environment for air drying

Check mark

Warnings and Cautions

Check mark

Ensure the device is switched off and disconnected before cleaning

Run this procedureArrow right

3 Monthly Battery Maintenance

Check mark

Battery Charging

Check mark

Charge the battery if it has been stored for 3 months without use.

Check mark

Charge the battery if the device has not been used for over 3 months and the battery was not removed.

Check mark

Battery Performance Check

Check mark

Check battery performance every 2 years.

Check mark

Check battery performance during device maintenance.

Check mark

Check battery performance if the battery is suspected to be the fault source.

Check mark

Battery Handling During Transport and Storage

Check mark

Remove the battery before transporting the device.

Run this procedureArrow right

SpO2 Probe Cleaning

Check mark

Cleaning the Probe and Lead Cable

Check mark

Use a soft cloth with detergent to wipe the probe and lead cable surface until there is no obvious dirt.

Check mark

Use a cotton swab with detergent to wipe the contact position between the probe and the patient until there is no obvious dirt.

Check mark

Rinsing and Drying

Check mark

Use a new cloth or paper towel with tap water to wipe away residual detergent until there is no obvious dirt.

Check mark

Use a dry soft cloth to wipe away residual water.

Check mark

Place the probe in a ventilated and shady environment for air drying.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Contec Medical Systems

Explore Other Assets