Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Brand Laboratory Pipette Transferpette
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Laboratory Pipette Testing
Attach a new pipette tip
Setting the nominal volume
Take up test liquid
Absorption of liquid not possible or very slow
Test with BRAND leak tester PLT unit or hold pipette vertically for approx. 10 s
Observe whether a drop forms at the pipette tip
If an error appears in the display of the PLT unit or a drop forms at the pipette tip, note the information
Dispense test liquid
Hold the pipette tip against the vessel wall and wipe it off
Laboratory Pipette Cleaning
Calibrate instrument before cleaning
Clean the pipette shaft
Check for media residues on the pipette shaft
Wipe the outside of the pipette shaft with a soft cloth
Clean the housing adequately
Check if minor soiling is permissible
Check for liquid residues in the instrument
Disassemble and clean the instrument if liquid residues are found
Refer to instructions for use for disassembly and cleaning
Laboratory Pipette Gravimetric Testing
For Transferpette® with nominal volume > 50 μl
Set 10 or 20% of the nominal volume.
Determine the temperature of the deionized water. Enter the result in the test report 4.
Place the weighing vessel on the balance and tare the balance.
Attach a new pipette tip and perform conditioning by taking up and dispensing test liquid five times.
Take up the test liquid from the receiving vessel.
Remove the weighing vessel from the balance.
Dispense the sample into the weighing vessel.
Place the weighing vessel on the balance and note the weight value. Enter the result in the test report 5.
3 Monthly Laboratory Pipette Inspection
Visual Inspection
Check for general damage on the housing
Inspect the pipette shaft tip for scratches on the surface
Examine the piston for scratches or dirt on the surface
Inspect the seal for scratches or dirt on the surface
Check the ejector unit for proper functionality
Access the parts list for your equipment in MaintainX.
Disposable Micropipette IntraEND 100 μl
709144
Pipette Holder
708605
Micro-Weighing Vessel
708470
Disposable Micropipette IntraEND 100 μl
709144
Pipette Holder
708605
Micro-Weighing Vessel
708470
Disposable Micropipette IntraEND 100 μl
709144
Pipette Holder
708605
Micro-Weighing Vessel
708470
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX