Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Goulds Pumps Vertical Turbine Pump VIT-FF 10D
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Thrust Pot Oil Level Inspection
Thrust pot lubrication guidelines
Verify that pumps are shipped without oil
Ensure oil-lubricated bearings are lubricated at the job site
Refer to Thrust Pot IOM for lubrication requirements
Check oil level when not operating
Measure oil level in the sight gauge
Is the oil level between 0.635 to 0.3175 mm (1/8 in. to 1/4 in.) from the top of the oil sight gauge?
Check oil level when operating
Is the oil level lower than the required level as indicated on the oil sight gauge?
Thrust Pot Oil Change
Thrust pot lubrication guidelines
Flush the oil reservoir to remove all grit particles in the oil reservoir sump.
Use the specified type of oil for flushing the reservoir.
Note any specific instructions from the Thrust Pot IOM for oil changing requirements.
1 Monthly Storage Pump Maintenance
2.4 Pump and bowl assembly storage requirements
Rotate the shaft and bowl assembly shaft counterclockwise at least 3 turns
Ensure the shaft is not left in a previous or extreme position
Check that the shaft rotates freely
2.4 Pump and bowl assembly storage requirements
Inspect the unit to ensure all preservatives are intact
Seal all pipe threads and flanged pipe covers with tape
Renew rust preventative on all uncoated surfaces
2.4.1 Extended long-term storage for partially assembled pumps
Mechanical Seal Inspection
Mechanical seal leaks
Allow time for seal adjustment if slight leaks occur at start-up
Run pump continuously if leaks decrease while running
Inspect for constant leaks during operation
Check for secondary seal damage or warped/cracked seal faces if constant leaks occur
Replacement guidelines — Mechanical seal checks
Check shaft or sleeve for pits, burrs, or sharp edges
Polish shaft or sleeve with fine emery cloth to remove burrs and sharp edges
Packing Adjustment
6.2 Adjust and replace the packing
Check conditions for packing adjustment
Is the leakage rate less than one drop per second?
Is the environment Ex-classified?
6.2.1 Adjust the packing when leaking is excessive
Tighten the gland nuts one-quarter turn with the pump in operation
Have the leaks decreased to a steady state of two drops per second?
Shut down the pump if leaks continue to exceed two drops per second
Allow the packing to compress until the gland is about to contact the upper face of the stuffing box
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX