Goulds Pumps Vertical Turbine Pump VIT-FF 10A
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3 Monthly Pump Inspection
6.1 Maintenance schedule
Check that the foundation and the hold-down bolts are tight
Thrust Pot Oil Change
Thrust pot lubrication guidelines
Flush the oil reservoir to remove all grit particles in the oil reservoir sump.
Use the specified type of oil for flushing the reservoir.
Refer to the Thrust Pot IOM for oil changing requirements.
Pump Maintenance
6.4 Disassembly
6.4.1 Disassembly precautions
Ensure safety precautions are followed
6.4.2 Disassemble the head and column
Remove necessary components based on drive type
Uncouple the driver or gear box from the pump shaft and mounting flanges
Remove all hold-down bolts and integral piping
Remove the coupling and mechanical seal
Continue disassembly down to the bowls
Enclosed Lineshaft Lubrication System Maintenance
Set up the lubrication system
Observe instructions on the submittal document
Fill the oil reservoir with oil
Check the lubricator feed and ensure the oil reservoir is flowing freely
Set the proper drops per minute on the regulator for shaft 0.75 to 1.00 in. (19 to 25 mm)
Set the proper drops per minute on the regulator for shaft 1.19 to 1.94 in. (30 to 50 mm)
Set the proper drops per minute on the regulator for shaft 2.19 in. and larger (55 mm and larger)
Is synthetic turbine oil ISO VG 32 used for general applications?
Consult ITT for more specific data if needed
Packing Adjustment
6.2 Adjust and replace the packing
Check conditions for packing adjustment
Is the leakage rate less than one drop per second after adjustment?
Is the environment Ex-classified?
6.2.1 Adjust the packing when leaking is excessive
Tighten the gland nuts one-quarter turn with the pump in operation
Has the leakage decreased to two drops per second?
Shut down the pump if leakage continues to exceed two drops per second
Allow the packing to compress until the gland is about to contact the upper face of the stuffing box
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX