Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Goulds Pumps Vertical Turbine Pump VIT-FF 11A
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Thrust Pot Lubrication
5.8 Lubricate the thrust pot during a shutdown period
Completely immerse the bearings in oil
Fill the oil reservoir until the oil runs over the oil retainer tube and down the shaft
Before startup, drain the oil to its required level
Thrust Pot Oil Level Inspection
Thrust pot lubrication guidelines
Verify lubrication requirements
Measure oil level when not operating
Is the oil level within the required range when not operating?
Is the oil level lower than the required level when operating?
Ensure pump is not operated if oil level is not at the required level
Enclosed Lineshaft Lubrication System Maintenance
4.4.11 Set up the lubrication system
Observe instructions on the submittal document.
Fill the oil reservoir with oil.
Check the lubricator feed and ensure the oil reservoir is flowing freely.
Set the proper drops per minute on the regulator based on shaft size.
Use synthetic turbine oil ISO VG 32 for general applications.
Consult ITT for more specific data if necessary.
Routine Pump Inspection
6.1 Maintenance schedule
Check for unusual noise, vibration, and bearing temperatures of thrust pot or electric motor
Ensure bearing housings are free from insulation and dust accumulation
Check the pump and piping for leaks
Analyze the vibration
Pump Maintenance
6.4 Disassembly
6.4.1 Disassembly precautions
Ensure safety precautions are followed
6.4.2 Disassemble the head and column
Remove necessary components based on drive type
Uncouple the driver or gear box from the pump shaft and mounting flanges
Remove all hold-down bolts and integral piping
Remove the coupling and mechanical seal
Continue disassembly down to the bowls
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX