Bradford White Water Heater EF100T399E3N2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Burner Tube Inspection
Service Procedure III — Burner Tube Inspection & Replacement
Burner Tube Removal
Turn the main power switch off and unplug the water heater, then turn off the gas supply.
Remove the surround cover, then disconnect the gas connection, PVC venting, wire harness, and silicone tubing from the gas valve.
Disconnect the wire harness from the blower assembly.
Remove the two screws holding the hot surface igniter and flame sensor and carefully remove them (for Direct Spark Ignition models, remove the spark rod bracket screws and spark rod instead).
Remove the four nuts holding the burner transition, lift the blower/gas valve/transition assembly off, and set the gasket aside.
Remove the burner tube from the burner mounting insert.
Burner Tube Inspection
Spark Rod Gap Inspection
Service Procedure IX — Spark Rod Gap Inspection and Adjustment (Direct Spark Ignition models)
Remove the combustion system per the Combustion System Removal procedure
Measure the spark gap between the spark rod and burner tube
Is the spark gap within the acceptable range of 3/16 in. to 1/4 in.?
Adjust the spark rod if the gap is out of range
Re-measure the spark gap to confirm it is within 3/16 in. to 1/4 in. after adjustment
Reinstall the combustion system
Check several ignitions to confirm the burner lights smoothly
Combustion System Testing
Service Procedure II — Combustion System Testing
Observe burner operation through the sight glass
Verify minimum gas supply piping size (3/4 in. NPT, or 1 in. NPT for EF100T399) and reconfigure piping if undersized
Confirm static inlet gas pressure is stable between 7 and 14 in. W.C.
Is the static inlet gas pressure stable?
For models with Hot Surface Ignition
Confirm the inlet gas pressure does not drop more than 2 in. W.C. during ignition
Does the igniter glow through the sight glass during warm-up?
Check for 120VAC at the ignition-module igniter terminals
Flame Sensor Testing
Service Procedure VIII — Flame Sensor Testing & Replacement
WARNING — 120-volt potential exposure; the flame sensor may be too hot to handle, so use caution.
Check for a minimum of 1 microamp during the 1.5-second flame-proving period
Is the flame-sensing circuit okay?
Check for the expected 24VAC at the ignition module/control board flame-establishing terminals
Is 24VAC present at the ignition module/control board flame-establishing terminals?
Call technical support if 24VAC is absent
With the sensor disconnected, check for continuity to ground
Replace the sensor and/or wire lead if continuity to ground is present
Intake Pressure Switch Testing
Service Procedure XII — Intake Pressure Testing (models prior to serial "CF" only)
Check continuity through the normally closed intake pressure switch if the blower does not energize
Refer to the vent safety switch, exhaust pressure switch, or blower testing procedures if the intake pressure switch is not faulty
Check continuity through the switch if the purge LED does not illuminate within the expected time
Confirm the inlet tube pressure tap reads at least -1.2 in. W.C. using a manometer
Remove the hose from the intake pressure switch and restart the heater to see if the purge LED illuminates
Isolate the heater from the intake vent system and restart again to isolate a switch versus vent-system fault if the purge LED illuminates
Check whether the intake vent system is obstructed and clear any obstruction found
Call technical support if no cause is found
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX