MaintainX, an Autodesk company
EnterprisePricing
Bradford White

Bradford White Water Heater EF60T125E3N2

Need answers fast?
Explore the manual using AI.

Bradford White Water Heater EF60T125E3N2
Bradford White Water Heater EF60T125E3N2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Bradford White Water Heater EF60T125E3N2

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Bradford White Water Heater EF60T125E3N2

Bradford White Water Heater EF60T125E3N2

Create an account to install this asset package.

Maintenance Plans for Bradford White Water Heater Model EF60T125E3N2

Integrate maintenance plans directly into your work orders in MaintainX.

Blower Testing

Check mark

Service Procedure V — Blower Testing & Replacement

Check mark

Warning: 120-volt potential exposure; use caution making voltage checks.

Check mark

Confirm the blower energizes when the thermostat calls for heat

Check mark

Check for 120VAC across the terminal-block black and white wires

Check mark

Check for 120VAC at the ignition module/control board and blower wiring

Check mark

Repair or replace the harness or blower as indicated

Check mark

Does the blower energize but seem weak?

Check mark

Check amp draw on the black blower-motor lead (should read 0.6–3.0 amps)

Check mark

Confirm the blower wheel is secure on the motor shaft

Run this procedureArrow right

Combustion System Testing

Check mark

Service Procedure II — Combustion System Testing

Check mark

Observe burner operation through the sight glass

Check mark

Verify minimum gas supply piping size

Check mark

Confirm static inlet gas pressure is stable between 7 and 14 in. W.C.

Check mark

Adjust or replace an inadequately sized regulator if pressure is unstable

Check mark

For models with Hot Surface Ignition

Check mark

Confirm the inlet gas pressure does not drop more than 2 in. W.C. during ignition

Check mark

Check that the igniter glows through the sight glass during warm-up

Check mark

Check for 120VAC at the ignition-module igniter terminals

Run this procedureArrow right

Flame Sensor Testing

Check mark

Service Procedure VIII — Flame Sensor Testing & Replacement

Check mark

Safety Warning

Check mark

Be cautious of 120-volt potential exposure and hot flame sensor

Check mark

Flame Sensor Testing

Check mark

Check for a minimum of 1 microamp during the 1.5-second flame-proving period

Check mark

Is the flame-sensing circuit okay?

Check mark

Check for expected 24VAC at ignition module/control board flame-establishing terminals

Check mark

Call technical support if 24VAC is absent

Check mark

With sensor disconnected, check for continuity to ground

Run this procedureArrow right

Thermostat Circuit Testing

Check mark

Service Procedure I — Thermostat Circuit Testing

Check mark

Error code 32

Check mark

Unplug electrical power to the water heater

Check mark

Check continuity of the wire harness to the sensor

Check mark

Is the resistance close to 0 ohms?

Check mark

Replace the harness if resistance exceeds 0.5 ohms or wires show damage

Check mark

Check sensor resistance against the temperature/resistance table

Check mark

Replace the sensor if needed

Check mark

Restore power and run the heater through a heating cycle

Run this procedureArrow right

Vent Safety Switch Testing

Check mark

Service Procedure XIII — Vent Safety Switch Testing and Replacement

Check mark

Warnings

Check mark

120-volt potential exposure; use caution making voltage checks.

Check mark

Confirm the exhaust collector compartment is not overheating (350°F) before resetting the switch; call technical support if there is evidence of overheating.

Check mark

Vent Safety Switch Testing

Check mark

Locate the harness connection and check continuity through the grey lead wires of the heater-side harness; call technical support if there is none.

Check mark

If continuity is present, depress the reset button on the high-limit switch and check for continuity across it, replacing the vent safety switch if there is none.

Check mark

Reset the heater and observe a heating cycle to confirm the switch does not reopen before 350°F is reached; replace the switch if it opens prematurely, and do not operate the heater if temperature exceeds 350°F without contacting technical support.

Check mark

Vent Safety Switch Replacement

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Bradford White

Explore Other Assets