Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bradford White Water Heater EF60T1503X2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Vent Safety Switch Testing
Service Procedure XIII — Vent Safety Switch Testing and Replacement
Warnings
120-volt potential exposure; use caution making voltage checks.
Confirm the exhaust collector compartment is not overheating (350°F) before resetting the switch; call technical support if there is evidence of overheating.
Vent Safety Switch Testing
Locate the harness connection and check continuity through the grey lead wires of the heater-side harness; call technical support if there is none.
If continuity is present, depress the reset button on the high-limit switch and check for continuity across it, replacing the vent safety switch if there is none.
Reset the heater and observe a heating cycle to confirm the switch does not reopen before 350°F is reached; replace the switch if it opens prematurely, and do not operate the heater if temperature exceeds 350°F without contacting technical support.
Vent Safety Switch Replacement
Hot Surface Igniter Testing
Service Procedure VII — Hot Surface Igniter Testing & Replacement
WARNING — 120-volt potential exposure; the igniter may be too hot to handle, so use caution.
Igniter's cold resistance check
Check the igniter's cold resistance
Is the igniter's cold resistance under 150 ohms?
Replace the hot surface igniter if resistance is not under 150 ohms
Ignition module voltage check
Check for 120VAC across the ignition module's igniter terminals during the warm-up period (igniter LED lit)
Is voltage present across the ignition module's igniter terminals?
Thermostat Circuit Testing
Service Procedure I — Thermostat Circuit Testing
Check error codes and conditions
Unplug electrical power to the water heater
Check continuity of the wire harness to the sensor
Check sensor resistance against the temperature/resistance table
Restore power and run the heater through a heating cycle
Error Code 65 (High Water Temperature)
Turn power off and draw water to cool the tank below 120°F
Check sensor and wire conditions
Anode Rod Inspection
Service Procedure XIV — Anode Inspection and Replacement
Turn off the water supply and drain the water heater
Disassemble the heater for access to anodes and flue baffles
Locate and remove the anode rods using a 1-1/16 in. hex socket
Visually inspect each anode rod for depletion
Apply thread sealing tape or compound and reinstall the anode rods
Restore the water supply and check for leaks
Repair any leaks found
Reinstall the collector cover
Spark Rod Gap Inspection
Service Procedure IX — Spark Rod Gap Inspection and Adjustment (Direct Spark Ignition models)
Remove the combustion system per the Combustion System Removal procedure
Measure the spark gap between the spark rod and burner tube
Is the spark gap within the acceptable range of 3/16 in. to 1/4 in.?
Carefully bend the spark rod if the gap is out of range
Re-measure to confirm the gap is within 3/16 in. to 1/4 in. after bending
Reinstall the combustion system
Check several ignitions to confirm the burner lights smoothly
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX