Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bradford White Water Heater EF100T300E3NA2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Intake Pressure Switch Testing
Service Procedure XII — Intake Pressure Testing (models prior to serial "CF" only)
Check continuity through the normally closed intake pressure switch if the blower does not energize
Replace the intake pressure switch if faulty
Refer to vent safety switch, exhaust pressure switch, or blower testing procedures if intake pressure switch is not faulty
Check continuity through the switch if the purge LED does not illuminate within the expected time
Confirm the inlet tube pressure tap reads at least -1.2 in. W.C. using a manometer
Remove the hose from the intake pressure switch and restart the heater to see if the purge LED illuminates
Isolate the heater from the intake vent system and restart again to isolate a switch versus vent-system fault
Check whether the intake vent system is obstructed
Thermostat Circuit Testing
Service Procedure I — Thermostat Circuit Testing
Check error codes
Unplug electrical power to the water heater
Check continuity of the wire harness to the sensor; resistance should be close to 0 ohms
Is the resistance of the wire harness to the sensor below 0.5 ohms?
Replace the harness if resistance exceeds 0.5 ohms or wires show damage
Check sensor resistance against the temperature/resistance table
Replace the sensor if needed
Restore power and run the heater through a heating cycle to verify proper operation
Hot Surface Igniter Testing
Service Procedure VII — Hot Surface Igniter Testing & Replacement
Safety Warning
Be aware of 120-volt potential exposure and handle the igniter with caution as it may be too hot.
Igniter Cold Resistance Check
Check the igniter's cold resistance
Is the igniter's cold resistance under 150 ohms?
Replace the hot surface igniter if resistance is not under 150 ohms
Ignition Module Voltage Check
Check for 120VAC across the ignition module's igniter terminals during the warm-up period (igniter LED lit)
Flue Baffle Inspection
Service Procedure XIV — Flue Baffle Inspection and Replacement
Warning: Heater components can be hot during this procedure; take precautions to avoid injury.
Disassemble the heater per the Disassembly Procedure for Access to Anodes & Flue Baffles.
Remove the flue baffles with pliers.
Visually inspect the baffles for oxidation and missing restrictors.
Replace any baffle with deteriorated oxidation or missing restrictors.
Reinstall the flue baffles once inspection or replacement is complete.
Reinstall the collector cover per the Collector Cover Installation Procedure.
Apply fresh silicone bead.
Blower Testing
Service Procedure V — Blower Testing & Replacement
Warning: 120-volt potential exposure; use caution making voltage checks.
Confirm the blower energizes when the thermostat calls for heat
Check for 120VAC across the terminal-block black and white wires
Check for 120VAC at the ignition module/control board and blower wiring
Repair or replace the harness or blower as indicated
Does the blower energize but seem weak?
Check amp draw on the black blower-motor lead (should read 0.6–3.0 amps)
Confirm the blower wheel is secure on the motor shaft
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX