MaintainX Asset Hub logo
EnterprisePricing
United Metal Products

United Metal Products Evaporative Cooler UMP-751 XL

Need answers fast?
Explore the manual using AI.

United Metal Products Evaporative Cooler UMP-751 XL
United Metal Products Evaporative Cooler UMP-751 XL

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for United Metal Products Evaporative Cooler UMP-751 XL

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

United Metal Products Evaporative Cooler UMP-751 XL

United Metal Products Evaporative Cooler UMP-751 XL

Create an account to install this asset package.

Maintenance Plans for United Metal Products Evaporative Cooler Model UMP-751 XL

Integrate maintenance plans directly into your work orders in MaintainX.

Blower Fan Assembly

Check mark

Safety Precautions

Check mark

Ensure guards are installed when the rotating fan prop or wheel is operating above an occupied space or within 7ft of working area.

Check mark

Is it deemed advisable to install guards for safety reasons?

Check mark

Motor Installation

Check mark

Place the motor on the adjustable motor base - either pivot plate or manual slide rail.

Check mark

Adjust motor as required to assure proper belt tension.

Check mark

Notes on motor location and belt alignment adjustments

Run this procedureArrow right

Propeller Fan Assembly

Check mark

Safety Note

Check mark

Install the sheave, pulley, and belt before setting the unit over the roof opening

Check mark

Place the motor on the flat side of the adjustable motor base

Check mark

Adjust motor base to assure proper belt tension

Run this procedureArrow right

Water Pump and Reservoir Cleaning

Check mark

Safety Precautions

Check mark

Disconnect power before servicing pump

Check mark

Pump Cleaning

Check mark

Snap the plastic grid off the bottom of the pump

Check mark

Clean the plastic grid

Check mark

Reservoir Maintenance

Check mark

Remove old debris from the reservoir

Check mark

Coat painted galvanized steel reservoirs with high quality sub-sealer

Run this procedureArrow right

Water Bleed-off System Maintenance

Check mark

Manual Bleed System Maintenance

Check mark

Measure the current pH level of the water

Check mark

Adjust the bleed-off flow rate

Check mark

Automatic Distributor Flush System Maintenance

Check mark

Adjust the timer for flush valve operation

Check mark

Ensure the timer is wired in series with the pump

Check mark

Seasonal Maintenance

Check mark

Dismantle and clean the flush valve

Check mark

General Maintenance

Run this procedureArrow right

Fluted Evaporative Cooler Media Maintenance

Check mark

Initial Inspection

Check mark

Check pads for salt build-up

Check mark

Is there significant scale build-up on the pads?

Check mark

Cleaning Procedure

Check mark

Are the pads scaled and plugged?

Check mark

Hose down pads to clean away dirt and salt particles

Check mark

Replacement Procedure

Check mark

Are the pads too blocked, reducing cooling efficiency and air delivery?

Check mark

Remove outer access panels and internal media cover plate

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from United Metal Products

Explore Other Assets