Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Trane Blower Coil Air Handler BCHE048BAA10A2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Weekly Unit Check
Safety Precautions
Ensure all electrical power is disconnected, including remote disconnects.
Discharge all energy storing devices such as capacitors.
Follow proper lockout/tagout procedures.
Ensure a qualified licensed electrician is present if working with live electrical components.
Observation and Inspection
Observe unit for any change in running condition.
Listen for any unusual noise from the unit.
Post Inspection
Circuit Module Replacement
Removing Old Circuit Module
Choose method for removing nylon standoffs
If using the latch method, are the standoffs retained on the metal panel?
Handling VelociTach Motor Control Board
Are you using an ESD protection wrist-strap?
Touch a grounded surface to discharge static buildup
Replacing Connectors
Replace connectors carefully onto the appropriate board
Is the green wire attached to the engine board white connector?
Battery Status Testing
WZS Battery Test
Push the Test button on the WZS sensor
Check LED5 on the sensor for battery strength indication
WDS Battery Test
Push the Test button on the WDS sensor
Check the display for battery life expectancy symbol
Fan Wheel Set Screws Check
Safety Precautions
Disconnect all electric power, including remote disconnects, before servicing.
Follow proper lockout/tagout procedures.
Verify that no power is present with a voltmeter.
Fan Wheel Set Screws Check
Check fan wheel set screws whenever a component is removed or an adjustment is made.
Refer to Table 44 for recommendations and note any adjustments made.
6 Monthly Fan Sections Inspection
Safety Precautions
Disconnect all electric power, including remote disconnects, before servicing.
Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized.
Inspection and Cleaning
Disconnect all electrical power to the unit.
Wear appropriate personal protective equipment.
Remove any contamination.
Vacuum the section with a HEPA filter vacuum device.
Clean contaminated areas with a mild bleach and water solution or an EPA-approved sanitizer.
Access the parts list for your equipment in MaintainX.
10K NTC Thermistor
X13790374010
10K NTC Thermistor
X13790374010
10K NTC Thermistor
X13790374010
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX