Tecan Austria

Tecan Austria Microplate Reader SPARK CYTO500

Need answers fast?
Explore the manual using AI.

Tecan Austria Microplate Reader SPARK CYTO500
Tecan Austria Microplate Reader SPARK CYTO500

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Tecan Austria Microplate Reader SPARK CYTO500

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Tecan Austria Microplate Reader SPARK CYTO500

Tecan Austria Microplate Reader SPARK CYTO500

Create an account to install this asset package.

Maintenance Plans for Tecan Austria Microplate Reader Model SPARK CYTO500

Integrate maintenance plans directly into your work orders in MaintainX.

Microplate Reader Absorbance Module Testing

Check mark

Uniformity 96-Well Plate

Check mark

Ensure all materials are available

Check mark

Pipette 200μl of the reagent into the wells of a Greiner 96-well plate according to the plate layout

Check mark

Calculate the Uniformity (CV%) using the formula: Uniformity (CV%) = (SDOG * 100) / meanOG

Check mark

Is the calculated Uniformity (CV%) within acceptable limits?

Check mark

Quality Control of the NanoQuant Plate

Check mark

Ensure all materials are available

Check mark

Pipette 2 μl of the reagent onto all positions of the NanoQuant Plate

Check mark

Start the NanoQuant application and perform average blanking procedure over all wells (16 positions)

Run this procedureArrow right

1 Daily Microplate Reader Injector Maintenance

Check mark

Inspection

Check mark

Inspect the syringes(s) for leaks

Check mark

Inspect the tubing for leaks

Check mark

System Flushing

Check mark

Flush the whole system with distilled or deionized water after each use

Check mark

Flush the whole system with distilled or deionized water when the syringe is not in use

Check mark

Syringe Maintenance

Check mark

Ensure syringes do not run dry for more than a few cycles

Run this procedureArrow right

Microplate Reader Cell Counting Module Testing

Check mark

Material Preparation

Check mark

Ensure all materials are available

Check mark

Procedure

Check mark

Adjust the cell suspension to a concentration of approximately 1x106 cells/ml

Check mark

Perform manual counting of cell suspension using a Neubauer chamber

Check mark

Pipette 10 μl of cell suspension into the counting chambers of a Tecan Cell Chip

Check mark

Load the cell chip into the adapter at position 1

Check mark

Start the Cell counting application

Check mark

Evaluation

Run this procedureArrow right

Microplate Reader NanoQuant Plate Cleaning

Check mark

Cleaning Procedure with Ultrasonic Bath

Check mark

Fill an ultrasonic bath with water and place a suitable beaker filled with distilled water into the ultrasonic bath.

Check mark

Switch on the ultrasonic and immerse the lid of the NanoQuant Plate into the beaker, with bobbing movements for about 20 seconds. Take care not to immerse the hinge of the plate.

Check mark

Repeat the procedure with the bottom part of the NanoQuant Plate.

Check mark

Remove any surplus water from the NanoQuant Plate with dry and oil-free compressed air.

Check mark

Cleaning Procedure with Kimwipe

Check mark

Moisten a laboratory Kimwipe with 70% ethanol and clean the inner and outer surfaces of the NanoQuant Plate.

Check mark

Moisten a piece of cotton or Kimwipe with distilled water and clean both sides of each quartz lens on the NanoQuant Plate.

Check mark

Wipe off any excess liquid with a dry Kimwipe.

Run this procedureArrow right

Microplate Reader Fluorescence Module Testing

Check mark

Detection Limit Top/Bottom 96-Well Plate

Check mark

Ensure all materials are prepared

Check mark

Prepare the instrument for measurement

Check mark

Start the measurement immediately after pipetting

Check mark

Pipette 200 μl for top measurement

Check mark

Pipette 350 μl for bottom measurement

Check mark

Enter the plate layout used

Check mark

Calculate and record the detection limit (DL)

Check mark

Uniformity Top/Bottom 96-Well Plate

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll